11 | FOREWORD |
13 | STATEMENT OF POLICY |
14 | PERSONNEL |
26 | SUMMARY OF CHANGES |
27 | 1. GENERAL 1.01 SCOPE 1.02 USE OF ILLUSTRATIONS 1.03 MANUFACTURER’S INFORMATION 1.04 REFERENCE TO SECTION IV 1.05 GLOSSARY OF TERMS |
40 | 2. TYPES OF BOILERS 2.01 CLASSIFICATION 2.02 STEEL BOILERS 2.03 CAST IRON BOILERS 2.04 MODULAR BOILERS 2.05 VACUUM BOILERS |
41 | FIGURES FIG. 2.02A-1 HORIZONTAL RETURN TUBE, BRICK-SET FIG. 2.02A-2 GAS FLOW PATTERNS OF SCOTCH-TYPE BOILERS |
42 | FIG. 2.02A-3 TYPE C FIREBOX BOILER FIG. 2.02A-4 THREE-PASS FIREBOX BOILER |
43 | FIG. 2.02A-5 LOCOMOTIVE FIREBOX BOILER FIG. 2.02A-6 VERTICAL FIRETUBE BOILER |
44 | FIG. 2.03A HORIZONTALSECTIONAL CAST IRON BOILER FIG. 2.03B VERTICALSECTIONAL CAST IRON BOILER FIG. 2.04A MODULES CONNECTED WITH PARALLEL PIPING FIG. 2.04B MODULES CONNECTED WITH PRIMARY-SECONDARY PIPING |
45 | 3. ACCESSORIES AND INSTALLATION 3.01 SAFETY AND SAFETY RELIEF VALVES 3.02 LOW- WATER FUEL CUTOFFS AND WATER FEEDERS 3.03 TRAPS 3.04 AIR ELIMINATORS FIGURES FIG. 3.01 OFFICIAL SYMBOL |
46 | 3.05 CONDENSATE RETURN PUMPS AND RETURN LOOP 3.06 VACUUM RETURN PUMP 3.07 CIRCULATORS ( CIRCULATING PUMPS) 3.08 EXPANSION TANK FIG. 3.01A SAFETY VALVE |
47 | FIG. 3.01B SAFETY RELIEF VALVE FIG. 3.02A FLOAT TYPE LOW-WATER CUTOFF |
48 | FIG. 3.02B ELECTRIC PROBE TYPE LOW-WATER CONTROL |
49 | 3.09 OIL PREHEATERS 3.10 FUEL OIL STORAGE AND SUPPLY SYSTEMS 3.11 PRESSURE GAGE FIG. 3.03-1 THERMOSTATIC TRAP FIG. 3.03-4 BUCKET TRAP WITH TRAP CLOSED FIG. 3.03-2 FLOAT TRAP FIG. 3.03-3 FLOAT AND THERMOSTATIC TRAP |
50 | 3.20 PRESSURE RELIEVING VALVE REQUIREMENTS FIG. 3.05 TYPICAL RETURN LOOP |
51 | FIG. 3.11 PRESSURE GAGES |
52 | TABLES TABLE 3.20MINIMUM POUNDS OF STEAM PER HOUR PERSQUARE FOOT OF HEATING SURFACE (kg/h/m2) |
54 | FIG. 3.20I SAFETY RELIEF VALVE DISCHARGE PIPE |
55 | 3.21 STEAM GAGES 3.22 WATER GAGE GLASSES 3.23 WATER COLUMN AND WATER LEVEL CONTROL PIPES |
56 | 3.24 PRESSURE CONTROL 3.25 PRESSURE OR ALTITUDE GAGES 3.26 THERMOMETERS 3.27 TEMPERATURE CONTROL 3.28 AUTOMATIC LOW- WATER FUEL CUTOFF AND/ OR WATER FEEDING DEVICE ( STEAM) |
57 | 3.29 LOW- WATER FUEL CUTOFF ( HOT WATER) 3.30 PIPING |
58 | 3.31 PROVISIONS FOR THERMAL EXPANSION IN HOT WATER SYSTEMS 3.32 STOP VALVES B. For Single Hot Water Heating Boilers C. For Multiple Boiler Installations. D. Type of Stop Valve( s) E. Identification of Stop Valves by Tags. |
59 | FIG. 3.30-1 SINGLE HOT WATER HEATING BOILER ā ACCEPTABLE PIPING INSTALLATION |
60 | FIG. 3.30-2 HOT WATER HEATING BOILERS IN BATTERY ā ACCEPTABLE PIPING INSTALLATION |
61 | FIG. 3.30-3 SINGLE STEAM BOILERS ā ACCEPTABLE PIPING INSTALLATION |
62 | FIG. 3.30-4A STEAM BOILERS IN BATTERY ā PUMPED RETURN ā ACCEPTABLE PIPING INSTALLATION |
63 | FIG. 3.30-4B STEAM BOILERS IN BATTERY ā GRAVITY RETURN ā ACCEPTABLE PIPING INSTALLATION |
64 | 3.33 BOTTOM BLOWOFF AND DRAIN VALVES 3.34 OIL HEATERS 3.35 SHUTDOWN SWITCHES AND CIRCUIT BREAKERS TABLE 3.31C-1EXPANSION TANK CAPACITIES FOR GRAVITYHOT WATER SYSTEMS TABLE 3.31C-2EXPANSION TANK CAPACITIES FOR FORCEDHOT WATER SYSTEMS TABLE 3.33SIZE OF BOTTOM BLOWOFF PIPING,VALVES, AND COCKS |
65 | 3.36 MODULAR BOILERS 3.37 VACUUM BOILERS 3.38 STORAGE TANKS FOR HOT WATER SUPPLY SYSTEMS |
66 | 4. FUELS 4.01 GAS ā NATURAL, MANUFACTURED, MIXED 4.02 LIQUEFIED PETROLEUM GAS ( LPG) 4.03 FUEL OILS |
67 | 4.04 COAL 4.05 ELECTRICITY |
68 | 5. FUEL BURNING EQUIPMENT AND FUEL BURNING CONTROLS 5.01 GAS BURNING EQUIPMENT 5.02 OIL BURNING EQUIPMENT FIGURES FIG. 5.01A ATMOSPHERIC GAS BURNER |
69 | FIG. 5.01C COMBINATION FUEL BURNERS FIG. 5.02A HIGH-PRESSURE ATOMIZING BURNER |
70 | 5.03 COAL BURNING EQUIPMENT 5.04 CONTROLS FIG. 5.02D HORIZONTAL ROTARY CUP FUEL OIL BURNER |
71 | FIG. 5.03-1 UNDERFEED SINGLE-RETORT STOKER FIG. 5.03-2 OVERTHROW RECIPROCATING PLATE-FEED TYPE SPREADER STOKER |
72 | FIG. 5.03-3 CHAIN GRATE STOKER WITH SECTION SHOWING LINKS |
74 | 6. BOILER ROOM FACILITIES 6.01 GENERAL 6.02 SAFETY 6.03 LIGHTING 6.04 VENTILATION 6.05 WATER AND DRAIN CONNECTIONS 6.06 FIRE PROTECTION 6.07 HOUSEKEEPING |
75 | 6.08 POSTING OF CERTIFICATES AND/ OR LICENSES 6.09 RECORDKEEPING, LOGS, ETC. |
76 | 7. OPERATION, MAINTENANCE, AND REPAIR ā STEAM BOILERS 7.01 STARTING A NEW BOILER AND HEATING SYSTEM |
77 | 7.02 STARTING A BOILER AFTER LAYUP ( SINGLE BOILER INSTALLATION) 7.03 CONDENSATION 7.04 CUTTING IN AN ADDITIONAL BOILER 7.05 OPERATION |
79 | 7.06 REMOVAL OF BOILER FROM SERVICE 7.07 MAINTENANCE |
81 | 7.08 BOILER REPAIRS 7.09 TESTS AND INSPECTIONS OF STEAM HEATING BOILERS |
85 | 8. OPERATION, MAINTENANCE, AND REPAIR ā HOT WATER BOILERS AND HOT WATER HEATING BOILERS 8.01 STARTING A NEW BOILER AND HEATING SYSTEM 8.02 STARTING A BOILER AFTER LAYUP ( SINGLE BOILER INSTALLATION) A. Procedure. |
86 | 8.03 CONDENSATION 8.04 CUTTING IN AN ADDITIONAL BOILER 8.05 OPERATION A. Check of Pressure and Temperature. |
87 | 8.06 REMOVAL OF BOILER FROM SERVICE 8.07 MAINTENANCE |
89 | 8.08 BOILER REPAIRS |
90 | 8.09 TESTS AND INSPECTIONS OF HOT WATER HEATING AND SUPPLY BOILERS |
93 | 9. WATER TREATMENT 9.01 SCOPE 9.02 CONSIDERATIONS 9.03 SERVICES OF WATER TREATMENT SPECIALISTS 9.04 CONFORMITY WITH LOCAL ORDINANCES 9.05 BOILER WATER TROUBLES 9.06 CHEMICALS USED |
94 | 9.07 FUNCTIONS OF CHEMICALS 9.08 TREATMENT ALTERNATIVES 9.09 BLOWDOWN |
95 | 9.10 FEEDERS 9.11 PROCEDURES 9.12 GLOSSARY OF WATER TREATMENT TERMS |
97 | MANDATORY APPENDIX I EXHIBITS |
108 | MANDATORY APPENDIX II SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE |
110 | MANDATORY APPENDIX III STANDARD UNITS FOR USE IN EQUATIONS |
111 | NONMANDATORY APPENDIX A GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE |
114 | INDEX |