{"id":435588,"date":"2024-10-20T07:50:26","date_gmt":"2024-10-20T07:50:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-1363-32023-tc\/"},"modified":"2024-10-26T14:51:03","modified_gmt":"2024-10-26T14:51:03","slug":"bs-1363-32023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-1363-32023-tc\/","title":{"rendered":"BS 1363-3:2023 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
188<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | 4 Conditions of use 5 General 6 General conditions for type testing <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | Table 1 \u2014 Schedule of tests <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | Figure 5 \u2014 Gauge for plug pins <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Figure 11 \u2014 GO gauge for socket-outlet <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | Figure 12 \u2014 Contact test gauge <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | Figure 14 \u2014 Non-contact test gauge <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | Figure 16a) \u2014 Withdrawal pull gauges for effectiveness of contact: Gauge for earthing socket contact 7 Classification and rating 7.1 Classifications <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | 7.2 Rating 8 Marking and labelling <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | Table 2 \u2014 Rated current and maximum fuse rating in normal use, and load for flexing and cable grip tests related to size of flexible cable <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | 9 Clearances, creepage distances and solid insulation <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | 9.1 Clearances <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | Table 3 \u2014 Minimum clearances for basic insulation 9.2 Creepage distances <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | Table 4 \u2014 Minimum creepage distances (mm) for basic insulation 9.3 Solid insulation Table 5 \u2014 Withstand voltages for insulation types <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | 9.4 Requirements for printed wiring boards and equivalent construction 10 Accessibility of live parts Figure 1 \u2014 Test pin <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | Figure 2a) \u2014 Apparatus for mechanical strength test on resilient covers <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | Figure 2b) \u2014 Hardwood block for Figure 2a) <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | 11 Provision for earthing <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | 12 Terminals and terminations of intermediate adaptors and adaptor plugs <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | Table 6 \u2014 Torque values for screws and nuts <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | 13 Construction of adaptors (plug portion) Figure 4a) \u2014 Dimensions and disposition of pins <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | Figure 4b) \u2014 Concave shrinkage allowance for ISODs <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | Figure 6 \u2014 Apparatus for testing plug cover fixing screws <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | Figure 32a) \u2014 Apparatus for tests on adaptor pins Figure 32b) \u2014 Apparatus for tests on adaptor plug pins <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | Figure 33 \u2014 Apparatus for torsion test on pins <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | Figure 7 \u2014 Mounting plate <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | Figure 8 \u2014 Plug pin deflection test apparatus for resilient adaptors <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | Figure 9 \u2014 Apparatus for abrasion test on insulating sleeves of plug pins <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | Figure 10 \u2014 Apparatus for pressure test at high temperature <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | 14 Construction of adaptors (adaptor socket-outlet portion) Figure 3 \u2014 Disposition of socket contacts <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | Figure 13 \u2014 Test apparatus and circuit for use with contact and non contact gauges <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | Figure 16b) \u2014 Withdrawal pull gauges for effectiveness of contact: Gauge for line and neutral current carrying socket contacts <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | Figure 35 \u2014 Simulated plug and cable devices <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | Figure 36 \u2014 Apparatus for calibration of turning moment of simulated plug Figure 37a) \u2014 Turning moment apparatus: Front view and side view <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | Figure 37b) \u2014 Turning moment apparatus: Top view and pictoral overview <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | Table 7 \u2014 Actuator test force 15 Resistance to ageing and to humidity 15.1 Resistance to ageing 15.2 Resistance to humidity <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | 16 Insulation resistance and electric strength <\/td>\n<\/tr>\n | ||||||
245<\/td>\n | 17 Temperature rise Figure 34 \u2014 Test plug <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | Table 8 \u2014 Permitted temperature rises <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | Figure 17a) \u2014 Test apparatus for temperature rise test <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | Figure 17b) \u2014 Dummy front plate for temperature rise test <\/td>\n<\/tr>\n | ||||||
251<\/td>\n | 18 Breaking capacity of adaptors 19 Normal operation of adaptors <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | 20 Connection of flexible cables and cable anchorage in intermediate adaptors and adaptor plugs <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | Figure 18 \u2014 Apparatus for flexing test <\/td>\n<\/tr>\n | ||||||
256<\/td>\n | Table 9 \u2014 Connection of flexible cables 21 Mechanical strength Figure 19 \u2014 Solid link for test on fuse clips <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | Figure 38 \u2014 Solid links for test on fuse clips <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | Figure 21a) \u2014 Pendulum impact test: General view of apparatus <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | Figure 21b) \u2014 Pendulum impact test: Constructional details of striking elements <\/td>\n<\/tr>\n | ||||||
260<\/td>\n | Figure 21c) \u2014 Pendulum impact test: Constructional details of mounting support for test samples <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | Figure 20 \u2014 Tumbling barrel <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | 22 Screws, current carrying parts and connections <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | 23 Resistance to heat <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | Figure 23 \u2014 Apparatus for pressure test <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | 24 Resistance to abnormal heat and fire 24.1 General 24.2 Glow wire test Table 10 \u2014 Application of glow wire test <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | 25 Resistance to excessive residual stresses and to rusting <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | 26 (Not used) 27 Overload tests <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | Annex A (normative)\u2002 Requirements for incorporated electronic components <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | Annex B (normative)\u2002 Pollution degree <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | Annex C (normative)\u2002 Relation between rated impulse withstand voltage, rated voltage and Overvoltage Category Table C.1 \u2014 Rated impulse withstand voltage for adaptors energized directly from the low voltage mains <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | Annex D (normative)\u2002 Determination of the Comparative Tracking Index and Proof Tracking Index Annex E (normative)\u2002 Impulse voltage test <\/td>\n<\/tr>\n | ||||||
277<\/td>\n | Table E.1 \u2014 Test voltages for verifying clearances at sea level Annex F (normative)\u2002 Measurement of clearances and creepage distances Table F.1 \u2014 Minimum values of width, X <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | Figure F.1 \u2014 Example 1 Figure F.2 \u2014 Example 2 Figure F.3 \u2014 Example 3 <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | Figure F.4 \u2014 Example 4 Figure F.5 \u2014 Example 5 Figure F.6 \u2014 Example 6 <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | Figure F.7 \u2014 Example 7 Figure F.8 \u2014 Example 8 Figure F.9 \u2014 Example 9 <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | Figure F.10 \u2014 Example 10 Figure F.11 \u2014 Example 11 Annex G (normative)\u2002 Test plug for temperature rise test <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | Figure 30 \u2014 Test plug for temperature rise <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | Annex H (normative)\u2002 The construction and calibration of a calibrated link <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | Figure 28 \u2014 Calibrated link <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | Figure 29 \u2014 Calibration jig for calibrated link <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | Annex I (informative)\u2002 Annex identification migration from 2016 edition to 2023 edition <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | Table I.1 \u2014 BS 1363 annex identification migration from 2016 to 2023 <\/td>\n<\/tr>\n | ||||||
290<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. 13 A plugs, socket-outlets, adaptors and connection units – Adaptors. Specification<\/b><\/p>\n |