{"id":293125,"date":"2024-10-19T19:54:51","date_gmt":"2024-10-19T19:54:51","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-1434-21997\/"},"modified":"2024-10-25T17:04:36","modified_gmt":"2024-10-25T17:04:36","slug":"bs-en-1434-21997","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-1434-21997\/","title":{"rendered":"BS EN 1434-2:1997"},"content":{"rendered":"
Electrical safety requirements are not covered by this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | BRITISH STANDARD <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Committees responsible for this British Standard <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword Foreword to amendment A1 Contents <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Temperature sensors 3.1 General Table 1 – Tolerances 3.2 Mechanical design <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Figure 1 – Temperature probes \u2014 Type DS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Figure 2 – Temperature probes \u2014 Type DL (head or cable) <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 3 – Temperature probes \u2014 Type PL (head or cable) <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 4 – Temperature pocket <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3.3 Platinum temperature sensor Figure 5 – Temperature probe with permanently connected signal leads Figure 6 – Head sensor temperature probe <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Table 2 – Maximum lengths of leads for Pt 100 temperature sensors <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 3.4 Other temperature sensors 4 Flow sensor 4.1 Maximum admissible working pressure, MAP 4.2 Sizes and dimensions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Table 3 – Dimensions Table 4 – Threaded end connections \u2014 Range of size and minimum thread lengths in mm 4.3 Test signal output 4.4 Adjusting device <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5 Calculators 5.1 Mechanical dimensions for calculators for domestic use 5.2 Terminals \u2014 Specification and identification Figure 7 – Outline of the dimensions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 8 – Maximum dimensions in mm <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 5 – Numbering of terminals <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 6 – Numbering and marking of the mains terminals 5.3 Batteries 5.4 Dynamic behaviour 5.5 Test signal output 5.6 24 hours interruption in supply voltage 6 Complete meter 7 Interfaces between sub-assemblies 7.1 Definitions for pulse device interfaces <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 7 – Timing and electrical parameters <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 8 – Timing and electrical parameters Table 9 – Compatibility 8 Marking and security seals 8.1 Marking <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.2 Sites for marking 8.3 Security seals <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Annex A (informative) Examples of temperature sensors <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Figure A.1 – Temperature probe \u2014 direct mounted \u2014 short \u2014 Type DS-cable <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure A.2 – Temperature probe \u2014 direct mounted \u2014 long \u2014 Type DL-head <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Figure A.3 – Temperature probe \u2014 direct mounted \u2014 long \u2014 Type DL-cable <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Figure A.4 – Temperature probe \u2014 pocket mounted \u2014 Type PL-head <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure A.5 – Temperature probe \u2014 pocket mounted \u2014 Type PL-cable <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure A.6 – Temperature probe boss and sealing ring <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure A.7 – Threaded pipe fitting G1\/2B, G3\/4B and G1B sizes <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure A.8 – Installation recommendations <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex B (normative) Input and output test signals Figure B.1 – Signal flow diagram <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Table B.1 – Input and output test signals for the EUT Table B.2 – Electrical and mechanical specifications for standardized test device <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Annex C Low voltage Power Supply for heat meters and their sub-assemblies Low voltage Power Supply for heat meters and their sub-assemblies C.1 Remote Supply C.1.1 Voltage (DC or AC) C.1.2 Current available C.1.3 Cabling requirements C.2 Local external DC supply C.2.1 Voltage C.2.2 Other Data Table C.1 – Standardized levels for external powering C.3 Power supply specification <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Heat meters – Constructional requirements<\/b><\/p>\n |