{"id":234284,"date":"2024-10-19T15:16:46","date_gmt":"2024-10-19T15:16:46","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-20-30409222-dc-2020\/"},"modified":"2024-10-25T09:49:18","modified_gmt":"2024-10-25T09:49:18","slug":"bsi-20-30409222-dc-2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-20-30409222-dc-2020\/","title":{"rendered":"BSI 20\/30409222 DC 2020"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
5<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | PASSIVE RF AND MICROWAVE DEVICES, INTERMODULATION LEVEL MEASUREMENT \u2013 1 Scope 2 Normative references 3 Abbreviations 4 General comments on PIM testing of filter assemblies 4.1 Sources of error: back-to-back filters <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Figure 1 \u2013 Typical receive band PIM test set-up 4.2 Environmental and dynamic PIM testing <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4.3 General test procedure 5 Example test equipment schematics for filter testing 5.1 General <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Table 1 \u2013 Summary table referencing example test equipment schematics for measuring PIM on filter-type devices 5.2 Transmit band testing Figure 3 \u2013 Typical test equipment schematic for measuring transmit-band, forward, passive IM products on an N-port DUT using two high-power carriers <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5.3 Receive band testing: dual high-power carriers Figure 4 \u2013 Typical test equipment schematic for measuring receive-band, forward, passive IM products on an N-port DUT, using two high-power carriers Figure 5 \u2013 Typical test equipment schematic for measuring receive-band, reverse, passive IM products on an N-port DUT, using two high-power carriers <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 6 \u2013 Typical test equipment schematic for measuring receive-band, passive IM products on an N-port DUT, using two high-power carriers 5.4 Receive band testing: injected interferer <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 7 \u2013 Typical test equipment schematic for measuring receive-band, forward, passive IM products on an N-port DUT, using the injected interferer technique Figure 8 \u2013 Typical test equipment schematic for measuring receive-band, reverse, passive IM products on an N-port DUT, using the injected interferer technique <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Figure 9 \u2013 Typical test equipment schematic for measuring receive-band, passive IM products on an N-port DUT, using the injected interferer technique <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 62037-5. Passive RF and microwave devices, intermodulation level measurement – Part 5. Measurement of passive intermodulation in filters<\/b><\/p>\n |