{"id":198432,"date":"2024-10-19T12:37:55","date_gmt":"2024-10-19T12:37:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-ag-1-2019\/"},"modified":"2024-10-25T05:10:55","modified_gmt":"2024-10-25T05:10:55","slug":"asme-ag-1-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-ag-1-2019\/","title":{"rendered":"ASME AG 1 2019"},"content":{"rendered":"
Provides requirements for the performance, design, construction, acceptance testing, and quality assurance of equipment used as components in nuclear safety-related air and gas treatment systems in nuclear facilities.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | COMMITTEE ROSTER <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | CORRESPONDENCE WITH THE COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | ORGANIZATION OF ASME AG-1 <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | ASME AG-1-2019 SUMMARY OF CHANGES <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Division I General Requirements SECTION AA COMMON ARTICLES AA-1100 SCOPE AA-1200 PURPOSE AA-1300 APPLICABILITY AA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | AA-3100 GENERAL AA-3200 MATERIAL SUBSTITUTION AA-3300 MATERIAL TESTING AA-3400 CERTIFICATION OF MATERIALS AA-4100 SCOPE <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Tables Table AA-3100-1 Allowable Materials <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | AA-4110 Environmental Qualification AA-4200 DESIGN CRITERIA AA-4210 Load Criteria <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | AA-4220 Stress Criteria: Limits AA-4230 Deflection Criteria: Limits AA-4240 Other Criteria Table AA-4212-1 Load Conditions Table AA-4230-1 Deflection Limits <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | AA-4300 DESIGN OF EQUIPMENT SYSTEMS AND THEIR SUPPORTING ELEMENTS AA-4310 General Requirements <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | AA-4320 Design Verification of Plate- and Shell-Type Components and Their Supporting Elements Table AA-4321-1 Plate- and Shell-Type Components: Primary Stress Allowables <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | AA-4330 Design Verification of Linear-Type Systems by Analysis Table AA-4323-1 Linear-Type Systems: Primary Stress Allowables <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | AA-4340 Functionality Requirements AA-4350 Design Verification by Seismic Qualification Testing <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Figures Figure AA-4355.3-1 Sine Beat Frequency and Amplitude Figure AA-4355.4-1 Sine Amplitude Decay Rate <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Figure AA-4356.4-1 Response Spectrum of Composite Excitation <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | AA-4360 Design of Bolts Figure AA-4356.4-2 Oscillations per Beat <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | AA-4400 DOCUMENTATION REQUIREMENTS AA-4410 Certification of Design Verification AA-4420 Equipment Description AA-4430 Safety-Related Features AA-4440 Report Content <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | AA-5100 GENERAL AA-5110 Scope and Applicability AA-5120 Responsibility for Procedures AA-5130 Measuring and Test Equipment AA-5200 VISUAL INSPECTION AA-5210 Scope AA-5220 Description of Method <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | AA-5230 Requirements AA-5240 Inspection Checklist AA-5250 Reports AA-5300 WELDED CONNECTIONS AA-5400 BOLTED CONNECTIONS AA-5410 Before Bolting AA-5420 After Bolting AA-5500 FABRICATION TOLERANCES AA-5600 PRESSURE AND LEAK TESTING AA-5700 PERFORMANCE AND FUNCTIONAL TESTING AA-5800 SEISMIC TESTING AA-6100 GENERAL AA-6110 Scope and Applicability AA-6120 Materials <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | AA-6130 Control of Fabrication and Installation Processes AA-6200 FABRICATION PROCESSES AA-6210 Cutting, Forming, and Bending AA-6220 Forming Tolerances AA-6230 Fitting and Aligning AA-6240 Welded Joints AA-6250 Mechanical Joints <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | AA-6300 WELDING REQUIREMENTS AA-6310 General <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | AA-6320 Workmanship AA-6330 Inspection and Testing of Welds <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Figure AA-6324.2-1 Acceptable and Unacceptable Weld Profiles <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | AA-6400 BRAZING AA-6410 General AA-6420 Workmanship <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | AA-6430 Inspection and Testing AA-6500 CLEANING AND COATING AA-6510 General <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | AA-6520 Design Considerations for Coating AA-6530 Repair of Coating System AA-6540 Cleanliness <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | AA-6550 Quality Assurance Requirements and Documentation AA-6600 INSTALLATION REQUIREMENTS AA-6610 Handling and Rigging AA-6620 Field Assembly <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | AA-6630 Temporary Field Attachments AA-7100 GENERAL AA-7110 Scope and Applicability AA-7120 Responsibility AA-7200 GENERAL REQUIREMENTS AA-7210 Planning, Procedures, and Instructions AA-7220 Personnel Qualifications <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | AA-7230 Classification of Items AA-7300 PACKAGING AA-7310 General AA-7320 Level of Packaging AA-7400 SHIPPING AA-8100 GENERAL AA-8110 Scope and Applicability AA-8120 Responsibility AA-8130 Responsibilities of Fabricators, Material Suppliers, and Material Manufacturers <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | AA-8200 IDENTIFICATION AND CONTROL OF ITEMS AA-8210 Documentation AA-8220 Identification and Completed Material AA-8230 Marking Requirements for Small Products AA-8240 Certified Material Test Reports AA-8250 Records of Examinations and Tests Figure AA-8130-1 Hierarchy of Responsibility <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | AA-8300 QUALITY ASSURANCE RECORDS AA-9100 SCOPE AND APPLICABILITY AA-9200 REQUIREMENTS AA-9210 Attachment of Nameplates AA-9220 Location of Nameplates AA-10100 GENERAL AA-10110 Scope AA-10120 Applicability <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | AA-10200 WELDING AA-10300 REPAIRS AA-10400 REPLACEMENTS AA-10410 Routine Maintenance AA-10420 Suitability AA-10430 Additional Documentation <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | AA-10500 RECORDS AA-10510 General Requirements AA-10520 Records Index AA-10530 Lifetime Records AA-10540 Nonpermanent Records Table AA-10530-1 Lifetime Repair and Replacement Records Table AA-10540-1 Nonpermanent Repair and Replacement Records <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | NONMANDATORY APPENDIX AA-A DESIGN AND QUALIFICATION BY ANALYSIS Table AA-A-1000-1 Analysis Considerations <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | AA-A-4100 AIR HANDLING UNIT (AHU) MODEL <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | AA-A-4200 FAN MODEL AA-A-4300 INSTRUMENTS AND CONTROLS (I & C) CABINETS AA-A-4400 DUCT SUPPORTS AA-A-4500 EQUIPMENT SUPPORTS AA-A-5100 STATIC LOADS <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | Figure AA-A-4200-1 Isometric View of a Typical Fan Model <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | Figure AA-A-4300-1 Isometric View of a Typical I & C Cabinet Model <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | Figure AA-A-4400-1 Isometric View of a Typical Duct Support Model <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | AA-A-5200 DYNAMIC ANALYSIS AA-A-5210 Dynamic Loads AA-A-5220 Dynamic Analysis Techniques AA-A-5230 Input Motion Figure AA-A-4500-1 Isometric View of a Typical Refrigeration Equipment Support <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | AA-A-5240 Two-Step Analysis AA-A-6100 STRESSES AA-A-6200 DEFLECTIONS AA-A-6210 Linear AA-A-6220 Nonlinear AA-A-6300 SUPPORT LOADS AA-A-6400 CONNECTION LOADING AA-A-6500 DEVICE LOADING AA-A-7100 SCOPE AA-A-7200 SAMPLE AHU ANALYSIS <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | Figure AA-A-7200-1 Computer Plots of Finite Element Model of Sample AHU (Perspective View of Tri-Plate Mesh) <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | AA-A-7300 DUCT SUPPORT (HANGER) SAMPLE PROBLEM AA-A-7310 Hanger Model AA-A-7320 Analysis <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Figure AA-A-7310-1 Typical Duct Support As-Built (Dimensions and Member Sizes Not Shown) <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Figure AA-A-7311-1 Ductwork Support Baseplate Model <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | Figure AA-A-7324-1 Effective Duct Cross Section <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | Figure AA-A-7325-1 Typical Duct System Model <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | NONMANDATORY APPENDIX AA-B SEISMIC QUALIFICATION BY TESTING AA-B-2100 PURPOSE AA-B-2200 SCOPE AA-B-2300 TEST SPECIMENS AA-B-2400 SPECIAL EQUIPMENT OR FIXTURES (IF REQUIRED) AA-B-2500 TEST SETUP AA-B-2600 TEST REQUIREMENTS AA-B-2700 ACCEPTANCE\/FAILURE CRITERIA AA-B-2800 TEST PROCEDURE <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | AA-B-2900 FINAL REPORT AA-B-3100 PURPOSE AA-B-3200 SCOPE AA-B-3300 TEST SPECIMENS AA-B-3400 SPECIAL EQUIPMENT OR FIXTURES AA-B-3500 TEST SETUP <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | AA-B-3600 TEST REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | AA-B-3700 ACCEPTANCE AND FAILURE CRITERIA AA-B-3800 TEST PROCEDURE AA-B-3900 FINAL REPORT <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | NONMANDATORY APPENDIX AA-C QUALIFICATION BY A COMBINATION OF ANALYSIS AND TESTING AA-C-3100 TESTING PROGRAM CONSIDERATIONS AA-C-4100 COMMON APPLICATIONS AA-C-4200 DYNAMIC AND STATIC SUPPORTING TESTS AA-C-4210 Dynamic Supporting Tests <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | AA-C-4220 Static Supporting Tests <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | SECTION AB SYSTEM DESIGN GUIDE AB-1100 SCOPE AB-1200 PURPOSE AB-1300 APPLICABILITY AB-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | AB-3100 POWER GENERATION FACILITIES AB-3110 Air Treatment Systems for DBA Requirements AB-3120 Normal Operation Systems AB-4100 SYSTEM FUNCTION AB-4200 SYSTEM BOUNDARIES AB-4300 SYSTEM INTERFACES <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | AB-4400 SYSTEM DESIGN AB-4410 SGTS Typical Components AB-4420 SGTS Required Design Parameters <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | AB-4500 SYSTEM OPERATION AB-4510 Recommendation for Control of Heat of Radioactive Decay and Heat of Oxidation AB-4600 SYSTEM INTERLOCKS AND ALARMS AB-5100 FILTER TRAIN COMPONENTS AB-5110 Description AB-5120 Applications <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | AB-5130 Cautions and Concerns AB-5140 Recommendations for Installation AB-5150 Recommendations for Maintainability AB-5160 Recommendations for Fire Detection <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | AB-5170 Recommendations for Fire Protection AB-5200 HEATERS AB-5210 Description AB-5220 Applications AB-5230 Cautions and Concerns AB-5240 Recommendations for Installation <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | AB-5250 Recommendations for Maintainability AB-5260 Recommendations for Fire Protection AB-5300 FANS AB-5310 Description AB-5320 Applications AB-5330 Cautions and Concerns AB-5340 Recommendations for Installation <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | AB-5350 Recommendations for Maintainability AB-5360 Recommendations for Fire Protection AB-5400 VALVES, PIPING, COOLING COILS AB-5410 Description AB-5420 Applications AB-5430 Cautions and Concerns <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | AB-5440 Recommendations for Installation AB-5450 Recommendations for Maintainability AB-5460 Recommendations for Fire Protection AB-5500 DUCT AND DAMPERS AB-5510 Description AB-5520 Applications AB-5530 Cautions and Concerns AB-5540 Recommendations for Installation AB-5550 Recommendations for Maintainability AB-5560 Recommendations for Fire Protection <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | AB-5600 INSTRUMENTATION AB-5610 Description AB-5620 Applications AB-5630 Cautions and Concerns AB-5640 Recommendations for Installation AB-5650 Recommendations for Maintainability AB-5660 Recommendations for Fire Protection AB-5700 HOUSINGS AB-5710 Description AB-5720 Applications AB-5730 Cautions and Concerns AB-5740 Recommendations for Installation <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | AB-5750 Recommendations for Maintainability AB-5760 Recommendations for Fire Protection AB-6100 SYSTEMS AB-6200 HOUSINGS AB-6300 COMPONENTS <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | AB-8100 Air Treatment Systems for DBA Requirements <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | Figure AB-8100-1 Typical Standby Gas Treatment Filtration System <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | Division II Ventilation Air Cleaning and Ventilation Air Conditioning SECTION BA FANS AND BLOWERS BA-1100 SCOPE BA-1200 PURPOSE BA-1300 APPLICABILITY BA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | BA-3100 GENERAL BA-3110 Material Stress Values BA-3200 SPECIAL LIMITATIONS ON MATERIALS BA-3300 DESIGNATION OF MATERIALS BA-3400 CERTIFICATION OF MATERIALS BA-3410 Centrifugal Fans BA-3420 Axial Fans BA-3500 PURCHASED MATERIALS BA-3600 DRIVER MATERIALS BA-4100 DESIGN CONDITIONS BA-4110 Performance <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | BA-4120 Environmental Conditions BA-4130 Loading BA-4140 Leakage <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | BA-4150 Support Boundary BA-4160 Vibration BA-4200 SELECTION BA-4210 Fans Table BA-4162-1 Maximum Allowable Displacement <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | BA-4220 Drivers BA-4300 CONSTRUCTION BA-4310 General BA-4320 Fans BA-4330 Drivers and Drives <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | BA-4340 Accessories <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | BA-4400 REPORTS AND CALCULATIONS BA-4410 Performance Rating BA-4420 Sound Level Data Report BA-4430 Structural Verification Considerations BA-5100 FAN INSPECTION AND TESTING BA-5110 General Testing Requirements <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | BA-5120 Performance Acceptance Tests BA-5130 Sound Tests BA-5140 Mechanical Tests <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | BA-5150 Test Results and Reports BA-5200 DRIVER INSPECTION AND TESTING BA-5210 First Unit of a Design BA-5220 Succeeding Units of a Design BA-6100 FABRICATION BA-6110 Selection of Materials BA-6200 INSTALLATION BA-7100 GENERAL BA-7200 PACKAGING BA-7300 SHIPPING BA-7400 RECEIVING BA-7500 STORAGE BA-7600 DRIVERS SHIPPED SEPARATELY BA-7610 Short-Term <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | BA-7620 Long-Term (Over 6 Months) BA-8100 GENERAL BA-8200 REQUIRED DOCUMENTATION FOR FANS BA-8210 Certified Fan Performance Curves BA-8220 Material Certification BA-8300 DRAWINGS AND DOCUMENTATION BA-9100 GENERAL BA-9200 FANS BA-9210 Required Nameplate Data BA-9220 Drivers BA-9300 ACCEPTABLE METHODS FOR MARKING ACCESSORIES BA-9400 OPERATING AND MAINTENANCE MANUALS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | NONMANDATORY APPENDIX BA-A FAN SYSTEM CONSIDERATIONS BA-A-1100 SYSTEM CHARACTERISTICS BA-A-1200 SYSTEM EFFECTS ON FAN PERFORMANCE BA-A-1300 FAN AND SYSTEM MATCHING BA-A-1400 FAN-SYSTEM CAPACITY CONTROL BA-A-1500 MULTIPLE FAN SYSTEMS <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | NONMANDATORY APPENDIX BA-B DIVISION OF RESPONSIBILITY <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | Table BA-B-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | SECTION DA DAMPERS AND LOUVERS DA-1100 SCOPE DA-1200 PURPOSE DA-1300 APPLICABILITY DA-1310 Exclusion of Items DA-1320 Exclusion of Specific Designs DA-1330 Boundary Limits DA-1400 DEFINITIONS AND TERMS DA-1410 Components DA-1420 Function <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | DA-1430 Configuration DA-1440 Leakage and Blade Operating Positioning DA-1450 Pressure DA-1460 Temperature DA-1470 Tests DA-1480 Construction DA-1490 Torque <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | DA-3100 ALLOWABLE MATERIALS DA-3110 Materials of Construction DA-3120 Allowable Stress DA-3130 Bearing Materials DA-3140 Seal Materials DA-3200 SPECIAL LIMITATIONS ON MATERIALS DA-3210 Metals DA-3220 Nonmetallic Materials DA-3230 Deterioration of Materials in Service DA-3300 CERTIFICATION OF MATERIALS <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | DA-4100 GENERAL DESIGN DA-4110 Requirements of Design Specifications DA-4120 Requirements of the Manufacturer DA-4130 Performance Requirements DA-4200 TECHNICAL REQUIREMENTS DA-4210 Structural <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | DA-4220 Thermal Expansion <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | DA-4230 Torque DA-4240 Linkage DA-4250 Bearings <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | DA-4260 Seals DA-4270 Frame Construction DA-4280 Mounting of Actuators and Accessories DA-4300 ACTUATORS DA-4310 Power-Operated Actuators <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | DA-4320 Manual Actuators DA-4330 Self-Contained Actuators DA-4340 Heat- or Temperature-Operated Actuators DA-4400 ACCESSORIES DA-4410 Accessory Requirements DA-4420 Auxiliary Energy Source DA-4430 Modulating Actuator Requirements DA-4440 Position Indicators DA-4450 Environmental Design Requirements DA-4460 Piping of Pneumatic Actuators DA-4470 Electrical Wiring Requirements DA-5100 TESTING <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | DA-5110 Pressure Drop Testing DA-5120 Cycle Time and Cycle Repetition DA-5130 Frame Leakage Testing for Frame Leakage Class A, B, or C DA-5140 Seat Leakage Testing DA-5141 Seat Leakage Test for Leakage Class 0 Dampers (Bubble Method). DA-5142 Seat Leakage Test for Leakage Class I Dampers. DA-5143 Seat Leakage Test for Leakage Class II or Class III Dampers or Louvers. DA-5144 Seat Leakage Test for Leakage Class IV Dampers and Louvers. DA-5145 Fire Damper Closure Test. DA-6100 WELDING AND BRAZING <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | DA-8100 DAMPER AND LOUVER PERFORMANCE DA-8300 QUALITY ASSURANCE RECORDS DA-9100 NAMEPLATES AND STAMPING DA-9200 MANUALS <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | MANDATORY APPENDIX DA-I SEAT AND FRAME LEAKAGE Table DA-I-1000-1 Maximum Permissible Seat Leakage Rate, scfm\/ft2 (scmh\/m2), of Damper or Adjustable Louver Face Area at 1 in. wg (25.4 mm wg) Differential Pressure Table DA-I-1000-2 Maximum Permissible Frame Leakage Rate Classes at Frame Design Pressure <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | MANDATORY APPENDIX DA-II DAMPER AND LOUVER CONFIGURATIONS Figure DA-II-1000-1 Parallel-Blade Dampers <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | Figure DA-II-1000-2 Wing-Blade Damper Figure DA-II-1000-3 Poppet Damper <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | Figure DA-II-1000-4 Opposed-Blade Damper Figure DA-II-1000-5 Single-Blade Damper <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | Figure DA-II-1000-6 Slide-Gate Guillotine Damper <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | Figure DA-II-1000-7 Curtain-Type Dampers <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | Figure DA-II-1000-8 Louver <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | NONMANDATORY APPENDIX DA-A DIVISION OF RESPONSIBILITY <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | Table DA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | SECTION SA DUCTWORK SA-1100 SCOPE SA-1200 PURPOSE SA-1300 APPLICABILITY SA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | Figure SA-1300-1 Ductwork and Ductwork Support \u2014 Interface Boundary <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | SA-3100 GENERAL SA-3200 MATERIAL SUBSTITUTION SA-3300 MATERIAL TESTING SA-3400 MATERIAL SPECIFICATIONS <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | SA-4100 GENERAL SA-4200 DESIGN CRITERIA SA-4210 Load Criteria <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | SA-4220 Stress Criteria SA-4230 Deflection Criteria SA-4240 Other Criteria SA-4300 DUCTWORK JOINTS AND SEAMS SA-4310 General SA-4320 Duct Joints and Seams <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | SA-4400 COMPONENTS SA-4410 Flexible Connections SA-4420 Gaskets SA-4430 Access Doors and Panels SA-4440 Ports for Testing and Maintenance SA-4450 Miscellaneous <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | SA-4500 PRESSURE BOUNDARY LEAKAGE SA-4510 General SA-4520 Applicability SA-4530 Evaluation <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | SA-4540 Leakage Testing SA-4600 DESIGN SPECIFICATION SA-5100 GENERAL SA-5110 Scope and Applicability SA-5120 Responsibility for Procedures SA-5200 VISUAL INSPECTION SA-5210 General Requirements SA-5220 Welded Connections SA-5230 Ductwork <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | SA-5240 Ductwork Supports SA-5300 PRESSURE BOUNDARY LEAKAGE TESTING SA-5310 General SA-5320 Systems Completeness SA-5330 Allowances for Testing System Leakage Rates by Sections SA-5340 Testing Procedures SA-5350 Documentation <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | SA-5360 Acceptance Criteria SA-5400 STRUCTURAL CAPABILITY TESTS SA-5410 Ductwork Pressure Test SA-5420 Longitudinal Seam Qualification Test SA-6100 GENERAL SA-6110 Scope and Applicability SA-6120 Materials SA-6130 Control of Installation and Fabrication Process SA-6140 Welding SA-6200 FABRICATION PROCESSES <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | SA-6300 MECHANICAL FASTENING SA-6400 FABRICATION TOLERANCES SA-6500 INSTALLATION TOLERANCES SA-6600 CLEANING, FINISHING, AND COATING SA-7100 GENERAL SA-7200 PACKAGING <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | Table SA-6400-1 Rectangular Ducts: Maximum Allowable Tolerances <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | Table SA-6400-2 Circular Ducts: Maximum Allowable Tolerances <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | SA-7300 SHIPPING SA-7400 RECEIVING SA-7500 STORAGE Table SA-6400-3 Flatness of Surface: Maximum Allowable Waviness Tolerance <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | SA-8100 GENERAL SA-8200 MATERIAL IDENTIFICATION SA-8300 DRAWINGS AND DOCUMENTATION SA-9100 GENERAL SA-9200 STAMPING\/MARKING SA-9210 Ducts SA-9220 Ductwork Supports SA-9230 Air Distribution Accessories <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | NONMANDATORY APPENDIX SA-A DIVISION OF RESPONSIBILITY Table SA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | NONMANDATORY APPENDIX SA-B PROCEDURES TO DETERMINE ALLOWABLE LEAKAGE FOR DUCTWORK SA-B-1100 PURPOSE SA-B-1200 ALLOWABLE LEAKAGE BY HEALTH PHYSICS CRITERIA SA-B-1210 General SA-B-1220 Procedure to Determine Allowable Leakage by Maximum Permissible Concentration Method <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | Figure SA-B-1221-1 Allowable Unit Leakage From Duct or Housing to Occupied Space <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | Figure SA-B-1222-1 System Parameters <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | SA-B-1230 Allowable Leakage by Iodine Protection Factor Reduction <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | Figure SA-B-1232.1-1 Control Room System Flow Diagram <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | Figure SA-B-1232.2-1 Control Room System Flow Diagram With Leakage Paths <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | Table SA-B-1234-1 Control Room Air Cleaning System Parameters for Leakage Analysis Table SA-B-1234-2 Control Room Air Conditioning System Parameters for Leakage Analysis <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | SA-B-1300 ADDITIONAL LEAKAGE CRITERIA SA-B-1310 Air Cleaning System Effectiveness SA-B-1320 Air Cooling Effectiveness SA-B-1330 System Quality SA-B-1400 AIR CLEANING SYSTEM CONFIGURATIONS AND LEAKAGE CLASSES SA-B-1410 Leakage Classes <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | Table SA-B-1310-1 Maximum Allowable Leakage Factors for Air Cleaning Effectiveness <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | Figure SA-B-1410-1 Single-Pass Air Cleaning System Configuration <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | Figure SA-B-1410-2 Recirculating Air Cleaning System Configurations <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | Figure SA-B-1410-3 Recirculating Air Cleaning System Configurations <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | NONMANDATORY APPENDIX SA-C ADDITIONAL GUIDELINES FOR DUCT DESIGN AND CONSTRUCTION SA-C-1100 INTRODUCTION SA-C-1200 GENERAL SA-C-1210 Access Doors SA-C-1220 Drains SA-C-1230 Duct <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | SA-C-1240 Access for Service, Testing, and Inspection SA-C-1300 DUCT CONSTRUCTION STANDARDS Table SA-C-1300-1 Duct Construction Standards <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | SECTION HA HOUSINGS HA-1100 SCOPE HA-1200 PURPOSE HA-1300 APPLICABILITY HA-1400 DEFINITIONS AND TERMS Figure HA-1300-1 Housing, Air Cleaning Unit: Walk-In Type <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Figure HA-1300-2 Housing, Air Cleaning Unit: Side-Access Type Figure HA-1300-3 Housing, Air Conditioning Unit: Walk-In Type <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | HA-3100 ALLOWABLE MATERIALS HA-3110 General Requirements HA-3120 Protective Coatings <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | HA-3200 SPECIAL LIMITATIONS ON MATERIALS HA-3210 Metals HA-3300 CERTIFICATION OF MATERIAL HA-4100 GENERAL DESIGN HA-4200 DESIGN CRITERIA HA-4210 Load Criteria <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | HA-4220 Stress Criteria HA-4230 Deflection Criteria HA-4240 Other Criteria Table HA-4212-1 Load Combinations <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | HA-4300 HOUSING JOINTS AND SEAMS HA-4310 General HA-4320 Housing Joints and Seams HA-4330 Air Cleaning Unit Joints and Seams HA-4340 Air Conditioning and Air Handling Units Housing, Joints and Seams <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | HA-4400 ACCESSORIES HA-4410 Gaskets HA-4420 Access Doors and Panels HA-4430 Provisions for Testing and Maintenance HA-4440 Miscellaneous <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | HA-4500 PRESSURE BOUNDARY LEAKAGE HA-4510 General HA-4520 Applicability HA-4530 Evaluation <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | HA-4600 DESIGN SPECIFICATION HA-5100 GENERAL HA-5110 Scope and Applicability HA-5120 Responsibility for Procedures HA-5200 INSPECTION HA-5210 General Requirements HA-5220 Housings <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | HA-5230 Housing Supports HA-5240 Filter Mounting Frame to Housing Weld Inspection HA-5300 PRESSURE BOUNDARY LEAKAGE TESTING HA-5310 Allowance for Housing Leakage Rates by Sections HA-5330 Testing Procedures HA-5340 Documentation HA-5350 Acceptance Criteria HA-5400 MOUNTING FRAME TO HOUSING LEAKAGE TEST HA-5500 STRUCTURAL CAPABILITY TEST HA-5600 AIRFLOW DISTRIBUTION TESTS <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | HA-5700 AIR-AEROSOL MIXING UNIFORMITY TESTS HA-5800 SAMPLING MANIFOLD TESTING HA-5900 AIR CONDITIONING AND AIR HANDLING UNIT TESTING HA-6100 GENERAL HA-6110 Scope and Applicability HA-6120 Materials HA-6130 Control of Installation and Fabrication Process HA-6140 Welding HA-6200 FABRICATION PROCESS HA-6210 Cutting, Forming, Bending, Aligning, and Fitting <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | HA-6300 MECHANICAL FASTENING HA-6310 General HA-6400 FABRICATION TOLERANCES HA-6410 General HA-6420 Side-Access Housing and Gasket Seal Surfaces HA-6430 Side-Access Housing Filter Fluid Seal Surfaces HA-6500 CLEANING HA-7100 GENERAL HA-7200 PACKAGING HA-7210 General HA-7220 Protection HA-7300 SHIPPING <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | HA-7400 RECEIVING HA-7500 STORAGE HA-7510 General HA-7520 Drains and Vents HA-7530 Other Components HA-8100 GENERAL HA-8200 MATERIAL IDENTIFICATION HA-8300 DRAWINGS AND DOCUMENTATION HA-9100 GENERAL HA-9200 STAMPING AND MARKING HA-9210 Housings HA-9220 Housing Accessories <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | NONMANDATORY APPENDIX HA-A DIVISION OF RESPONSIBILITY Table HA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | NONMANDATORY APPENDIX HA-B ADDITIONAL GUIDELINES FOR HOUSING DESIGN AND CONSTRUCTION HA-B-1100 INTRODUCTION HA-B-1200 GENERAL HA-B-1210 Access Doors HA-B-1220 Drains <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | NONMANDATORY APPENDIX HA-C MANIFOLD DESIGN GUIDELINES HA-C-1100 INTRODUCTION HA-C-1200 MANIFOLD REQUIREMENTS FOR IN-PLACE TESTS HA-C-1210 Airflow HA-C-1220 Challenge\/Air Mixing Uniformity HA-C-1230 Multiple-Component Banks in Series HA-C-1240 Absence of Components in Series HA-C-1250 Uniformity HA-C-1300 CONSIDERATIONS FOR USE OF PERMANENTLY INSTALLED MANIFOLDS HA-C-1310 HA-C-1320 HA-C-1330 <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | HA-C-1340 HA-C-1350 HA-C-1400 INJECTION MANIFOLDS HA-C-1410 HA-C-1420 HA-C-1430 Figure HA-C-1230-1 Common Configurations Requiring Test Manifolds (Plan A) <\/td>\n<\/tr>\n | ||||||
217<\/td>\n | HA-C-1440 General Rules Applicable to All Injection Manifolds HA-C-1450 Figure HA-C-1230-2 Common Configurations Requiring Test Manifolds (Plan B) <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | HA-C-1460 HA-C-1470 HA-C-1480 HA-C-1490 HA-C-1500 SAMPLE MANIFOLDS HA-C-1510 Figure HA-C-1230-3 Common Configurations Requiring Test Manifolds (Plan C) <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | Figure HA-C-1230-4 Common Configurations Requiring Test Manifolds (Plan D) <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | Figure HA-C-1230-5 Common Configurations Requiring Test Manifolds (Plan E) <\/td>\n<\/tr>\n | ||||||
221<\/td>\n | HA-C-1520 HA-C-1530 HA-C-1540 <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | NONMANDATORY APPENDIX HA-D PERFORMANCE TEST FOR QUALIFICATION OF SAMPLING MANIFOLDS HA-D-1100 PURPOSE HA-D-1200 LIMITS HA-D-1300 TEST REQUIREMENTS HA-D-1400 TEST METHOD <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | HA-D-1500 ACCEPTANCE CRITERIA HA-D-1510 Single-Point Sample HA-D-1520 Sample Manifold HA-D-1600 DOCUMENTATION HA-D-1700 ACCEPTANCE OF RESULTS <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | SECTION RA REFRIGERATION EQUIPMENT RA-1100 SCOPE RA-1200 PURPOSE RA-1300 APPLICABILITY RA-1310 Clarification of Code Applicability RA-1320 Exclusion of Components RA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
225<\/td>\n | RA-3100 GENERAL MATERIAL REQUIREMENTS RA-3110 Pressure-Retaining Materials <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | RA-3120 Component Support Materials RA-3130 Materials for Nonmetallic Components RA-3140 Electrical Materials RA-3150 Pump and Compressor Materials RA-3160 Valve, Piping, and Fitting Materials RA-3170 Welding and Brazing Materials RA-4100 PURPOSE RA-4200 DESIGN SPECIFICATION <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | RA-4300 EQUIPMENT PERFORMANCE REQUIREMENTS RA-4400 MECHANICAL DESIGN REQUIREMENTS RA-4410 Waterside System <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | RA-4420 Refrigerant Side System RA-4430 Lubrication System <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | RA-4500 STRUCTURAL DESIGN REQUIREMENTS RA-4510 General RA-4520 Equipment Attachment Boundary RA-4600 ELECTRICAL DESIGN REQUIREMENTS RA-4610 Electric Motors RA-4620 Electric Valve and Vane Actuators RA-4630 Control Systems RA-4640 Electrical Wiring, Splices, and Connections <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | RA-4700 MAINTENANCE CRITERIA RA-5100 RATING RA-5200 TESTING RA-5210 Pressure Vessel Testing <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | RA-5220 Functional Testing of Motors <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | RA-5300 EXAMINATION RA-5310 Nondestructive Examination RA-6100 WELDING AND BRAZING RA-6110 Welding RA-6120 Brazing RA-6130 Welding and Brazing of Non-ASME BPVC Pressure-Retaining Components and Supports <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | RA-6200 CLEANING, FINISHING, AND COATING RA-6210 Cleanliness RA-6220 Cleaning and Finishing RA-6230 Finishing and Surface Preparation <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | RA-6240 Coating and Application RA-6300 INSTALLATION RA-7100 GENERAL REQUIREMENTS RA-7200 PACKAGING RA-7210 ASME BPVC, Section III Equipment RA-7220 ASME BPVC, Section VIII Equipment RA-7230 Motors Shipped Separately <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | RA-7300 SHIPPING RA-7310 ASME BPVC Section III Equipment RA-7320 ASME BPVC, Section VIII Equipment RA-7400 STORAGE RA-7410 ASME BPVC, Section III Equipment RA-7420 ASME BPVC, Section VIII Equipment RA-7500 HANDLING AND RIGGING RA-7510 ASME BPVC, Section III Equipment RA-7520 ASME BPVC Section VIII Equipment <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | RA-7600 ASSEMBLY, ERECTION, AND START-UP RA-7610 Field-Assembled or Field-Erected Equipment RA-7620 External Connections and Services RA-7630 Start-Up and Periodic Testing RA-8100 GENERAL RA-9100 GENERAL REQUIREMENTS RA-9200 NAMEPLATES AND STAMPING RA-9300 DATA REPORTS <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | Forms FORM RA-1 CENTRIFUGAL COMPRESSOR TEST RECORD <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | FORM RA-1a CENTRIFUGAL COMPRESSOR OIL PUMP PRESSURE TEST <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | FORM RA-1b CENTRIFUGAL COMPRESSOR PRESSURE TEST RECORD <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | FORM RA-2 RECIPROCATING SCROLL\/SCREW COMPRESSOR TEST RECORD <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | FORMRA-2a RECIPROCATING SCROLL\/SCREW COMPRESSOR PRESSURE TEST RECORD <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | FORM RA-3 ELECTRICAL TEST RECORD \u2014 CONTROLS AND CONTROL PANELS <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | FORM RA-4 PERFORMANCE TEST RECORD (U.S. CUSTOMARY) <\/td>\n<\/tr>\n | ||||||
245<\/td>\n | FORM RA-M4 PERFORMANCE TEST RECORD (SI) <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | MANDATORY APPENDIX RA-I PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (U.S. CUSTOMARY) RA-I-1100 TEST CONDITIONS RA-I-1200 EFFECT OF FOULING FACTOR RA-I-1300 HEAT BALANCE EQUATION RA-I-1400 MEASURED HEAT BALANCE RA-I-1500 TABULATION OF CAPACITY RA-I-1600 POWER INPUT RA-I-1700 REFRIGERATION MACHINES EQUIPPED WITH SUBCOOLERS <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | Table RA-I-1100-1 Test Conditions Table RA-I-1200-1 Effect of Fouling Factor Table RA-I-1300-1 Heat Balance Equation <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | Table RA-I-1500-1 Tabulation of Capacity <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | MANDATORY APPENDIX RA-MI PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (SI) RA-MI-1100 TEST CONDITIONS RA-MI-1200 EFFECT OF FOULING FACTOR RA-MI-1300 HEAT BALANCE EQUATION RA-MI-1400 MEASURED HEAT BALANCE RA-MI-1500 TABULATION OF CAPACITY RA-MI-1600 POWER INPUT RA-MI-1700 REFRIGERATION MACHINES EQUIPPED WITH SUBCOOLERS <\/td>\n<\/tr>\n | ||||||
251<\/td>\n | Table RA-MI-1100-1 Test Conditions Table RA-MI-1200-1 Effect of Fouling Factor <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | Table RA-MI-1300-1 Heat Balance Equation Table RA-MI-1500-1 Tabulation of Capacity <\/td>\n<\/tr>\n | ||||||
253<\/td>\n | MANDATORY APPENDIX RA-II MANDATORY LIST OF INSTRUMENTATION FUNCTIONS AND CONTROL FUNCTIONS Table RA-II-1000-1 Mandatory List of Instrumentation Functions and Control Functions <\/td>\n<\/tr>\n | ||||||
254<\/td>\n | NONMANDATORY APPENDIX RA-A DIVISION OF RESPONSIBILITY <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | Table RA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | NONMANDATORY APPENDIX RA-B TYPICAL EXTERNAL INTERFACE DIAGRAMS Figure RA-B-1000-1 Interface Points \u2014 Typical Two-Vessel Design <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | SECTION CA CONDITIONING EQUIPMENT CA-1100 SCOPE CA-1200 PURPOSE CA-1300 APPLICABILITY CA-1310 Clarification of Code Applicability CA-1320 Exclusion of Components CA-1330 Interfacing Boundaries CA-1400 DEFINITIONS AND TERMS CA-1410 General CA-1420 Water, Steam, and Volatile Refrigerant Coils <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | CA-1440 Electric Heating Coils CA-3100 MATERIAL SPECIFICATIONS <\/td>\n<\/tr>\n | ||||||
260<\/td>\n | CA-3200 WATER, STEAM, AND VOLATILE REFRIGERANT COIL MATERIALS CA-3210 Pressure-Retaining Materials for Water and Steam Coils CA-3220 Pressure-Retaining Materials for Volatile Refrigerant Coils CA-3230 Non-Pressure-Retaining Materials CA-3240 Load-Bearing Members CA-3250 Non-Load-Carrying Members CA-3400 ELECTRIC HEATING COIL MATERIALS CA-3500 CERTIFICATION OF MATERIALS <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | CA-4100 DESIGN CONDITIONS FOR WATER AND STEAM COILS CA-4110 Design Specification CA-4120 Technical Requirements <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | CA-4130 Structural Requirements for Water, Steam, and Volatile Refrigerant Coils Table CA-4122-1 Maximum Water Velocities in Water Coils <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | CA-4200 DESIGN CONDITIONS FOR VOLATILE REFRIGERANT COILS CA-4210 Design Specification CA-4220 Technical Requirements <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | CA-4400 DESIGN CONDITIONS FOR ELECTRIC HEATING COILS CA-4410 Design Specification CA-4420 Technical Requirements <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | CA-4430 Structural Requirements for Electric Heating Coils <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | CA-5100 GENERAL REQUIREMENTS CA-5200 TESTING OF WATER, STEAM, AND VOLATILE REFRIGERANT COILS CA-5210 Performance Verification and Validation <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | CA-5220 Pressure Testing for Water and Steam Coils CA-5230 Pressure Testing for Volatile Refrigerant Coils CA-5240 Nondestructive Examination CA-5400 TESTING OF ELECTRIC HEATING COILS CA-5410 General Requirements CA-5420 Functional Test CA-5430 Dielectric Withstand Test CA-5440 Resistance Test <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | CA-5450 Nondestructive Examination CA-5500 TEST REPORTS CA-6100 GENERAL REQUIREMENTS CA-6110 Introduction CA-6120 Welding CA-6130 Brazing CA-6140 Mechanical Joining CA-6200 CLEANING, FINISHING, AND COATING CA-6210 Cleaning and Finishing <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | CA-6220 Finishing and Surface Preparation CA-6230 Coating and Application CA-7100 GENERAL REQUIREMENTS CA-7200 PACKAGING CA-7300 SHIPPING <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | CA-7400 STORAGE CA-7500 HANDLING CA-8100 GENERAL REQUIREMENTS CA-8110 Introduction CA-8120 Documentation and Retention CA-9100 GENERAL REQUIREMENTS CA-9200 COILS <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | CA-9300 INFORMATION ON NAMEPLATES CA-9310 Water, Steam, and Volatile Refrigerant Coils CA-9320 Electric Heating Coils CA-9400 NAMEPLATE VISIBILITY Table CA-8121-1 Lifetime Quality Assurance Records Table CA-8121-2 Nonpermanent Quality Assurance Records <\/td>\n<\/tr>\n | ||||||
272<\/td>\n | CA-9500 DATA REPORTS CA-9510 Coils CA-9520 Volatile Refrigerant Coils CA-10100 GENERAL <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | NONMANDATORY APPENDIX CA-A DIVISION OF RESPONSIBILITY Table CA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | NONMANDATORY APPENDIX CA-B DESIGN RECOMMENDATIONS CA-B-1100 SCOPE CA-B-1200 GENERAL RECOMMENDATIONS <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | SECTION FA MOISTURE SEPARATORS FA-1100 SCOPE FA-1200 PURPOSE FA-1300 APPLICABILITY FA-1310 Moisture Separators FA-1320 Limitations FA-1400 DEFINITIONS AND TERMS FA-3100 ALLOWABLE MATERIALS FA-3110 Pads FA-3120 Filter Cases, Cross Grids, and Supports FA-3130 Rivets FA-3140 Gaskets FA-3150 Adhesive FA-3200 LIMITATIONS <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | FA-3300 MATERIAL CERTIFICATION FA-4100 GENERAL DESIGN FA-4200 TECHNICAL REQUIREMENTS FA-4210 Design Requirements FA-4220 Moisture Separator Assembly FA-4300 STRUCTURAL REQUIREMENTS FA-4310 General FA-4320 Load Definition FA-4330 Load Combinations FA-4340 Acceptance Criteria FA-5100 QUALIFICATION TESTS FA-5110 Moisture Separator Rough Handling Qualifications FA-5120 Moisture Separator Airflow Resistance Test <\/td>\n<\/tr>\n | ||||||
277<\/td>\n | Figure FA-4100-1 Typical Moisture Separation Configuration Table FA-4100-1 Moisture Separator Performance Specifications <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | FA-5130 Moisture Separator Performance Test FA-5200 PRODUCTION INSPECTION AND TESTING FA-5210 Dimensional Inspection FA-5220 Welding Inspection FA-5230 Moisture Separator Airflow Resistance Test FA-6100 REPAIRS FA-6200 CLEANING FA-6300 TOLERANCES FA-6310 Flatness and Squareness FA-6320 Overall Dimensions FA-8100 RESPONSIBILITY FA-8200 DOCUMENTATION <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | FA-8300 CERTIFICATE OF CONFORMANCE FA-9100 MOISTURE SEPARATOR MARKING FA-9200 PACKAGE MARKING <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | NONMANDATORY APPENDIX FA-A DIVISION OF RESPONSIBILITY Table FA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | SECTION FB MEDIUM EFFICIENCY FILTERS FB-1100 SCOPE FB-1200 PURPOSE FB-1300 APPLICABILITY FB-1310 Limitations FB-1320 Responsibility FB-1400 DEFINITIONS AND TERMS FB-3100 ALLOWABLE MATERIALS FB-3110 Media FB-3120 Filter Frames <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | FB-3130 Separators FB-3140 Sealants and Adhesives FB-3150 Gaskets FB-3200 SPECIAL LIMITATIONS OF MATERIALS FB-4100 GENERAL DESIGN FB-4200 DESIGN CRITERIA FB-4300 STRUCTURAL REQUIREMENTS FB-5100 INSPECTION PLAN FB-5110 Plan FB-5120 Minimum Inspection Requirements FB-5130 Rejection and Reinspection FB-5200 QUALIFICATION TESTING FB-5210 Testing Requirements <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | FB-5220 Certification FB-5230 Requalification FB-5240 Seismic Qualification FB-6100 GENERAL FB-6200 MANUFACTURE AND ASSEMBLY FB-6210 Flatness and Squareness FB-6220 Overall Dimensions FB-7100 GENERAL FB-8100 GENERAL FB-8200 DOCUMENTATION FB-9100 FILTER MARKINGS <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | FB-9200 PACKAGE MARKING <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | NONMANDATORY APPENDIX FB-A DIVISION OF RESPONSIBILITY Table FB-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | SECTION FC HEPA FILTERS FC-1100 SCOPE FC-1200 PURPOSE FC-1300 APPLICABILITY FC-1310 HEPA Filters FC-1320 Limitations FC-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | FC-3100 ALLOWABLE MATERIALS FC-3110 Case Materials FC-3120 Gasket Materials <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | FC-3130 Filter Media FC-3140 Faceguards FC-3150 Adhesives FC-3160 Separators FC-3170 Ancillary Accessories FC-3200 SPECIAL LIMITATIONS OF MATERIALS FC-3210 Alternate Materials FC-4100 GENERAL DESIGN FC-4110 HEPA Filters FC-4120 Filter Case FC-4130 Filter Pack <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | Figure FC-4110-1 Type A, C, or D Metal-Cased, Gasket-Sealed Filter Figure FC-4110-2 Type A Wood Case Separator Filter <\/td>\n<\/tr>\n | ||||||
290<\/td>\n | Figure FC-4110-3 Type B Mini Pleat Filter Figure FC-4110-4 Type C Separatorless Filter <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | Figure FC-4110-5 Type D Thread Separator Filter Table FC-4110-1 Nominal Sizes and Ratings <\/td>\n<\/tr>\n | ||||||
292<\/td>\n | FC-4140 Gaskets FC-4150 Separators Figure FC-4142-1 Gel Seal Filter Corner \u2014 Isometric <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | FC-4160 Face Guards FC-4200 PERFORMANCE REQUIREMENTS FC-4210 Test Aerosol Particle Penetration FC-4220 Resistance to Airflow FC-4300 SEISMIC QUALIFICATION FC-5100 QUALIFICATION TESTING <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | FC-5110 Resistance to Airflow FC-5120 Test Aerosol Particle Penetration FC-5130 Resistance to Rough Handling FC-5140 Resistance to Pressure Table FC-5100-1 Test Groups and Sequence Table FC-5120-1 Acceptable Test <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | FC-5150 Resistance to Heated Air FC-5160 Spot Flame Resistance FC-5170 Structural Requirements FC-5200 INSPECTION FC-5300 PRODUCTION TESTING FC-6100 GENERAL REQUIREMENTS Table FC-5140-1 Test Conditions and Requirements <\/td>\n<\/tr>\n | ||||||
296<\/td>\n | FC-6200 MANUFACTURE AND ASSEMBLY FC-6210 Tolerances FC-6220 Medium Installation FC-6300 WORKMANSHIP FC-8100 RESPONSIBILITY FC-8200 CERTIFICATE OF CONFORMANCE FC-9100 FILTER MARKING FC-9200 PACKAGE MARKING <\/td>\n<\/tr>\n | ||||||
297<\/td>\n | MANDATORY APPENDIX FC-I \u200a <\/td>\n<\/tr>\n | ||||||
298<\/td>\n | NONMANDATORY APPENDIX FC-A DIVISION OF RESPONSIBILITY Table FC-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
299<\/td>\n | SECTION FD TYPE II ADSORBER CELLS FD-1100 SCOPE FD-1200 PURPOSE FD-1300 APPLICABILITY FD-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
300<\/td>\n | FD-3100 ALLOWABLE MATERIALS FD-3110 Adsorbent FD-3120 Screens FD-3130 Casing FD-3140 Gaskets and Seal Pads FD-3150 Adhesive FD-3160 Threaded Fasteners FD-3170 Rivets FD-3200 LIMITS FD-3300 CERTIFICATION OF MATERIALS FD-3310 Metal Parts FD-3320 Gaskets and Seal Pads FD-3330 Adhesive FD-3340 Threaded Fasteners FD-3350 Hardware Items (Washers and Rivets) FD-4100 GENERAL DESIGN FD-4200 TECHNICAL REQUIREMENTS FD-4210 Design Requirements <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | Figure FD-4100-1 Type II Adsorber Cell <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | FD-4220 Adsorber Bed FD-4230 Case and Assembly FD-4300 STRUCTURAL REQUIREMENTS FD-4310 General FD-4320 Load Definition FD-4330 Load Combinations FD-4340 Acceptance Criteria <\/td>\n<\/tr>\n | ||||||
303<\/td>\n | FD-5100 DIMENSIONAL INSPECTION FD-5200 WELDING INSPECTION FD-5210 Spot Welds FD-5220 Other Welds FD-5300 QUALIFICATION TESTS FD-5310 Design Qualification FD-5320 Filling Method Qualification FD-5330 Acceptance Tests Table FD-5332-1 Detector Sensitivity for Leak Test <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | FD-6100 DIMENSIONS AND TOLERANCES FD-6200 WELDING AND BRAZING FD-6210 Testing and Inspection FD-6220 Repairs FD-6300 FILLING FD-6400 CLEANING FD-7100 PACKAGING FD-7200 LOADING FOR SHIPMENT FD-7300 STORAGE Table FD-6100-1 Cell Dimensions and Tolerances <\/td>\n<\/tr>\n | ||||||
305<\/td>\n | FD-7400 CONTAINERS FD-8100 DOCUMENTATION FD-9100 PERMANENT NAMEPLATE FD-9200 FILLING LABEL <\/td>\n<\/tr>\n | ||||||
306<\/td>\n | MANDATORY APPENDIX FD-I CALCULATION OF RESIDENCE TIME OF ADSORBER CELLS <\/td>\n<\/tr>\n | ||||||
307<\/td>\n | MANDATORY APPENDIX FD-II SAMPLE CANISTERS FD-II-1100 SCOPE FD-II-1200 APPLICABILITY FD-II-1300 DEFINITIONS AND TERMS FD-II-2100 TECHNICAL REQUIREMENTS FD-II-2110 Design Requirements FD-II-2120 Sample Canister Casing FD-II-2130 Assembly <\/td>\n<\/tr>\n | ||||||
308<\/td>\n | Figure FD-II-2000-1 Examples of Sample Canister Configurations <\/td>\n<\/tr>\n | ||||||
309<\/td>\n | Figure FD-II-2110-1 Detail of a Typical 2-in. Sample Canister <\/td>\n<\/tr>\n | ||||||
310<\/td>\n | NONMANDATORY APPENDIX FD-A DIVISION OF RESPONSIBILITY Table FD-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
311<\/td>\n | SECTION FE TYPE III ADSORBERS FE-1100 SCOPE FE-1200 PURPOSE FE-1300 APPLICABILITY FE-1310 Type III Adsorbers FE-1320 Adsorbents FE-1330 Limitations FE-1340 Responsibility FE-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
312<\/td>\n | FE-3100 ALLOWABLE MATERIALS FE-3110 Adsorbent FE-3120 Screens and Casing FE-3130 Gaskets and Seal Pads FE-3140 Other Components FE-4100 GENERAL FE-4110 Type III Adsorbers FE-4120 Adsorber Service Equipment FE-4200 TECHNICAL REQUIREMENTS FE-4210 Design Criteria <\/td>\n<\/tr>\n | ||||||
313<\/td>\n | Figure FE-4110-1 Horizontal Section of Type III Adsorber Bed <\/td>\n<\/tr>\n | ||||||
314<\/td>\n | FE-4220 Sizing FE-4300 ADSORBENT BED DETAILS FE-4400 STRUCTURAL REQUIREMENTS FE-4410 General FE-4420 Load Definition FE-4430 Load Combinations FE-4440 Acceptance Criteria <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | FE-4500 ADSORBENT HANDLING SUBSYSTEMS FE-4510 Adsorbent Loading System FE-4520 Adsorbent Removal System FE-4600 AUXILIARY SYSTEMS FE-4610 Sampling of Installed Adsorbents <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | FE-4620 Fire Protection FE-5100 GENERAL FE-5200 VISUAL INSPECTION FE-5300 DIMENSIONAL INSPECTION FE-5310 Bed Depth <\/td>\n<\/tr>\n | ||||||
317<\/td>\n | FE-5320 Screens FE-5330 Adsorbent Reservoir FE-5400 WELDING INSPECTION FE-5410 Spot Welds FE-5420 Seal Welds FE-5500 FABRICATION TOLERANCES FE-5600 DESIGN QUALIFICATION FE-5610 Functional Design Qualification FE-5620 Filling Method Qualification FE-5630 Seismic Qualification FE-5700 ACCEPTANCE TESTS FE-6100 GENERAL FE-6200 WELDING FE-6300 CLEANING FE-6400 CONSTRUCTION AND INSTALLATION FE-6500 REPAIRS <\/td>\n<\/tr>\n | ||||||
318<\/td>\n | FE-7100 TYPE III ADSORBERS FE-7200 ADSORBENT MATERIALS FE-8100 GENERAL FE-8200 INSPECTION REPORTS AND DOCUMENTATION FE-9100 PERMANENT NAMEPLATES FE-9200 FILLING LABEL <\/td>\n<\/tr>\n | ||||||
319<\/td>\n | MANDATORY APPENDIX FE-I RESIDENCE TIME CALCULATION <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | MANDATORY APPENDIX FE-II SCREEN WAVINESS INSPECTION TEST <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | MANDATORY APPENDIX FE-III ADSORBER FILLING QUALIFICATION TEST PROCEDURE FE-III-4100 ADSORBENT CHARACTERISTICS FE-III-4110 Bed Volume FE-III-4120 Adsorbent Weight FE-III-4130 Particle Size Distribution FE-III-4200 PACKING DENSITY FE-III-4300 ADSORBENT LOSSES <\/td>\n<\/tr>\n | ||||||
323<\/td>\n | MANDATORY APPENDIX FE-IV TYPE III ADSORBER QUALIFICATION TEST PROCEDURE <\/td>\n<\/tr>\n | ||||||
324<\/td>\n | FE-IV-4100 APPARATUS FE-IV-4200 TEST PROCEDURE Figure FE-IV-3000-1 Adsorbate Distribution Curves <\/td>\n<\/tr>\n | ||||||
325<\/td>\n | FE-IV-4300 RH MEASUREMENT FE-IV-4400 RH BREAKTHROUGH FE-IV-4500 ADSORBENT SAMPLING FE-IV-4600 MOISTURE CONTENT Figure FE-IV-4100-1 Test Adsorber Setup <\/td>\n<\/tr>\n | ||||||
326<\/td>\n | MANDATORY APPENDIX FE-V SAMPLE CANISTERS FE-V-1100 SCOPE FE-V-1200 APPLICABILITY FE-V-1300 DEFINITIONS AND TERMS FE-V-2100 TECHNICAL REQUIREMENTS FE-V-2110 Design Requirements FE-V-2120 Sample Canister Casing FE-V-2130 Assembly <\/td>\n<\/tr>\n | ||||||
328<\/td>\n | NONMANDATORY APPENDIX FE-A VISUAL INSPECTION RECOMMENDATIONS FOR TYPE III ADSORBERS FE-A-1100 ADSORBER SECTIONS FE-A-1200 ADSORBER ASSEMBLY FE-A-1300 ADSORBER SERVICE SYSTEMS FE-A-1400 INSPECTION OPENINGS FE-A-1500 LABELING <\/td>\n<\/tr>\n | ||||||
329<\/td>\n | NONMANDATORY APPENDIX FE-B DIVISION OF RESPONSIBILITY Table FE-B-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | SECTION FF ADSORBENT MEDIA FF-1100 SCOPE FF-1200 PURPOSE FF-1300 APPLICABILITY FF-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | FF-4100 GENERAL DESIGN FF-4200 ADSORBENT DEGRADATION FF-4210 Desorption FF-4220 Degradation <\/td>\n<\/tr>\n | ||||||
332<\/td>\n | FF-5100 PHYSICAL TESTING FF-5110 Before Impregnation FF-5120 After Impregnation FF-5200 RADIOACTIVE TESTING FF-5210 Qualification Tests FF-5220 Radioactive Batch Tests FF-5300 ACCEPTABLE ASTM STANDARDS FF-7100 PROTECTION OF ADSORBENT MEDIA <\/td>\n<\/tr>\n | ||||||
333<\/td>\n | FF-7200 STORAGE FF-7300 CONTAINERS FF-8100 DOCUMENTATION <\/td>\n<\/tr>\n | ||||||
334<\/td>\n | NONMANDATORY APPENDIX FF-A DIVISION OF RESPONSIBILITY Table FF-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
335<\/td>\n | SECTION FG MOUNTING FRAMES FOR AIR-CLEANING EQUIPMENT FG-1100 SCOPE FG-1200 LIMITATIONS FG-1300 PURPOSE FG-1400 RESPONSIBILITY FG-3100 ALLOWABLE MATERIALS FG-3200 MATERIAL LIMITATIONS FG-4100 GENERAL DESIGN FG-4110 HEPA Filter Mounting Frames <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | FG-4120 Type II Adsorber Cell Mounting Frames Figure FG-4110-1 Typical Filter Mounting Frame <\/td>\n<\/tr>\n | ||||||
337<\/td>\n | Figure FG-4120-1 Typical Type II Adsorber Mounting Frame <\/td>\n<\/tr>\n | ||||||
338<\/td>\n | FG-4130 Medium Efficiency Filter Mounting Frames FG-4140 Moisture Separator Mounting Frames FG-4141 Moisture Separator Mounting Frame Dimensions. FG-4142 Moisture Separator Clamping. FG-4143 Moisture Separator Support. Figure FG-4140-1 Typical Moisture Separator Mounting Frame Figure FG-4140-1 Typical Moisture Separator Mounting Frame <\/td>\n<\/tr>\n | ||||||
339<\/td>\n | FG-4144 Penetrations. FG-4150 Common Requirements FG-4151 Galling Prevention. FG-4200 STRUCTURAL REQUIREMENTS FG-4210 General FG-4220 Load Definition FG-4230 Load Combinations FG-4240 Acceptance Criteria FG-4300 STRUCTURAL DESIGN ANALYSIS FG-4310 Filter Mounting Frame Deflection Limits <\/td>\n<\/tr>\n | ||||||
340<\/td>\n | FG-4320 Type II Adsorber Cell and Moisture Separator Mounting Frame Deflection Limits FG-4330 Pressure Impulse Loading FG-5100 DIMENSIONAL INSPECTION FG-5200 ALIGNMENT AND SURFACE FINISH FOR HEPA FILTER AND TYPE II ADSORBER CELL MOUNTING FRAMES FG-5210 HEPA Filter and Type II Adsorber Cell Mounting Frame Alignment FG-5220 HEPA Filter and Type II Adsorber Cell Mounting Frame Flatness FG-5230 HEPA Filter and Type II Adsorber Cell Mounting Frame Dimensions <\/td>\n<\/tr>\n | ||||||
341<\/td>\n | FG-5240 HEPA Filter and Type II Adsorber Cell Mounting Frame Surface Finish FG-5300 ALIGNMENT AND SURFACE FINISH FOR MEDIUM EFFICIENCY FILTER AND MOISTURE SEPARATOR MOUNTING FRAMES FG-5310 Medium Efficiency Filter and Moisture Separator Mounting Frame Alignment FG-5320 Medium Efficiency Filter and Moisture Separator Mounting Frame Flatness FG-5330 Medium Efficiency Filter and Moisture Separator Mounting Frame Dimensions FG-5340 Medium Efficiency Filter and Moisture Separator Mounting Frame Surface Finish FG-5400 WELD INSPECTION FG-5500 COATING INSPECTION FG-6100 GENERAL FG-6200 WELDING FG-6300 CLAMPING DEVICES FG-6400 CLEANING FG-6500 COATING <\/td>\n<\/tr>\n | ||||||
343<\/td>\n | NONMANDATORY APPENDIX FG-A DIVISION OF RESPONSIBILITY <\/td>\n<\/tr>\n | ||||||
344<\/td>\n | Table FG-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
346<\/td>\n | SECTION FH OTHER ADSORBERS FH-1100 SCOPE FH-1200 PURPOSE FH-1300 APPLICABILITY FH-1400 DEFINITIONS AND TERMS FH-3100 ALLOWABLE MATERIALS FH-3110 Adsorbent FH-3120 Screens FH-3130 Casing FH-3140 Adhesives and Sealants FH-3150 Rivets FH-3200 LIMITS FH-3300 CERTIFICATION OF MATERIALS <\/td>\n<\/tr>\n | ||||||
347<\/td>\n | FH-3310 Fabricated Metal Parts FH-3320 Gaskets and Seal Pads FH-3330 Adhesives and Sealants FH-3340 Purchased Hardware Items (Washers and Rivets) FH-4100 GENERAL DESIGN Figure FH-4100-1 Type IV \u201cV\u201d Adsorbers Model (Fluid Seal Version) <\/td>\n<\/tr>\n | ||||||
348<\/td>\n | FH-4200 TECHNICAL REQUIREMENTS FH-4210 Design Requirements Figure FH-4100-2 Type IV \u201cV\u201d Bed Adsorbers Model (Gasketed Version) <\/td>\n<\/tr>\n | ||||||
349<\/td>\n | FH-4220 Adsorber Beds FH-4230 Case and Assembly Figure FH-4100-3 Type IV \u201cV\u201d Adsorbers Model, Exploded View <\/td>\n<\/tr>\n | ||||||
350<\/td>\n | FH-4240 Gaskets FH-4250 Gel Seals FH-4300 STRUCTURAL REQUIREMENTS FH-4310 General FH-4320 Load Definition Figure FH-4100-4 Type IV \u201cU\u201d Bed Adsorbers Model (Gasketed Version) <\/td>\n<\/tr>\n | ||||||
351<\/td>\n | FH-4330 Load Combinations FH-4340 Acceptance Criteria FH-5100 DIMENSIONAL INSPECTION FH-5200 WELDING INSPECTION FH-5210 Spot Welds FH-5220 Other Welds FH-5300 QUALIFICATION TESTS FH-5310 Filling Method Qualification FH-5400 ACCEPTANCE TESTS FH-5410 Airflow Resistance Test <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | FH-5420 Refrigerant Leak Test FH-6100 DIMENSIONS AND TOLERANCES FH-6200 WELDING FH-6210 Testing and Inspection FH-6220 Repairs FH-6300 FILLING FH-6400 CLEANING FH-7100 PACKAGING Table FH-6100-1 Dimensional Requirements <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | FH-7200 LOADING FOR SHIPMENT FH-7300 STORAGE FH-7400 CONTAINERS FH-8100 DOCUMENTATION FH-9100 PERMANENT NAMEPLATE FH-9200 FILLING LABEL <\/td>\n<\/tr>\n | ||||||
354<\/td>\n | NONMANDATORY APPENDIX FH-A DIVISION OF RESPONSIBILITY Table FH-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
355<\/td>\n | SECTION FI METAL MEDIA FILTERS <\/td>\n<\/tr>\n | ||||||
356<\/td>\n | SECTION FJ LOW EFFICIENCY FILTERS FJ-1100 SCOPE FJ-1200 PURPOSE FJ-1300 APPLICABILITY FJ-1310 Limitations FJ-1320 Responsibility FJ-1400 DEFINITIONS AND TERMS FJ-3100 ALLOWABLE MATERIALS FJ-3110 Filter Media <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | FJ-3120 Filter Frame FJ-3130 Separators FJ-3140 Sealants and Adhesives FJ-3150 Gaskets FJ-3200 SPECIAL LIMITATIONS OF MATERIALS FJ-4100 GENERAL DESIGN FJ-4110 MERV 1\u20135 Filters FJ-4120 MERV 6\u20138 Filters FJ-4200 DESIGN CRITERIA FJ-4300 STRUCTURAL REQUIREMENTS FJ-5100 INSPECTION PLAN FJ-5110 Inspection Requirements FJ-5120 Rejection and Reinspection FJ-5200 QUALIFICATION TESTING <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | FJ-5210 Testing Requirements FJ-5220 Certification FJ-5230 Requalification FJ-5240 Seismic Qualification FJ-6100 GENERAL FJ-6200 MANUFACTURE AND ASSEMBLY FJ-6210 Tolerances FJ-7100 GENERAL FJ-8100 GENERAL FJ-8200 DOCUMENTATION FJ-9100 FILTER MARKINGS <\/td>\n<\/tr>\n | ||||||
359<\/td>\n | FJ-9200 PACKAGE MARKINGS <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | NONMANDATORY APPENDIX FJ-A DIVISION OF RESPONSIBILITY Table FJ-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
361<\/td>\n | SECTION FK SPECIAL HEPA FILTERS FK-1100 SCOPE FK-1200 PURPOSE FK-1300 APPLICABILITY FK-1310 Special HEPA Filters FK-1320 Limitations FK-1330 Service Life FK-1340 Division of Responsibility FK-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
363<\/td>\n | FK-3100 ALLOWABLE MATERIALS FK-3110 Cases, End Caps, Grilles, and Flange Materials FK-3120 Gasket Material FK-3130 Filter Media FK-3140 Face guards FK-3150 Adhesives FK-3160 Separators <\/td>\n<\/tr>\n | ||||||
364<\/td>\n | FK-3170 Grilles FK-3200 GENERAL MATERIAL REQUIREMENTS FK-3210 Special Limitations of Materials FK-3220 Alternate Materials FK-4100 GENERAL DESIGN FK-4110 Special HEPA Filters Table FK-4111-1 Type 1 Radial Flow HEPA Filter \u2014 Nominal Rating <\/td>\n<\/tr>\n | ||||||
365<\/td>\n | Figure FK-4111-1 Type 1 Radial Flow HEPA Filter (Internal Gasket), Midsection View <\/td>\n<\/tr>\n | ||||||
366<\/td>\n | FK-4120 Filter End Cap, Grilles, and Flange FK-4130 Filter Pack Figure FK-4111-2 Type 1 Radial Flow HEPA Filter (Internal Gelatinous Seal), Midsection View <\/td>\n<\/tr>\n | ||||||
367<\/td>\n | Figure FK-4111-3 Type 1 Radial Flow HEPA Filter (External Gasket), Midsection View <\/td>\n<\/tr>\n | ||||||
368<\/td>\n | FK-4140 Gaskets Figure FK-4111-4 Type 1 Radial Flow HEPA Filter (External Gelatinous Seal), Midsection View <\/td>\n<\/tr>\n | ||||||
369<\/td>\n | Figure FK-4112-1 Type 2 Axial Flow Circular HEPA Filters <\/td>\n<\/tr>\n | ||||||
370<\/td>\n | FK-4150 Grilles FK-4160 Face guards FK-4200 PERFORMANCE REQUIREMENTS FK-4300 STRUCTURAL REQUIREMENTS FK-5100 QUALIFICATION TESTING FOR TYPE 1 RADIAL FLOW FILTERS Table FK-4112-1 Type 2 Axial Flow Circular HEPA Filter \u2014 Nominal Rating <\/td>\n<\/tr>\n | ||||||
371<\/td>\n | FK-5110 Resistance to Airflow FK-5120 Test Aerosol Particle Penetration Table FK-4200-1 Performance Requirements <\/td>\n<\/tr>\n | ||||||
372<\/td>\n | FK-5130 Resistance to Rough Handling FK-5140 Resistance to Pressure Table FK-5100-1 Test Groups and Sequence \u2014 Type 1 Radial Flow HEPA Filters Table FK-5140-1 Test Conditions and Requirements <\/td>\n<\/tr>\n | ||||||
373<\/td>\n | FK-5150 Resistance to Heated Air FK-5160 Spot Flame Resistance FK-5200 QUALIFICATION TESTING FOR TYPE 2 AXIAL FLOW CIRCULAR FILTERS <\/td>\n<\/tr>\n | ||||||
374<\/td>\n | FK-5210 Resistance to Airflow FK-5220 Test Aerosol Particle Penetration FK-5230 Resistance to Rough Handling FK-5240 Resistance to Pressure Table FK-5200-1 Test Groups and Sequence \u2014 Type 2 Axial Flow Circular HEPA Filters <\/td>\n<\/tr>\n | ||||||
375<\/td>\n | FK-5250 Resistance to Heated Air FK-5260 Spot Flame Resistance FK-5400 QUALIFICATION TESTING FOR TYPE 4 AXIAL FLOW RECTANGULAR FILTERS <\/td>\n<\/tr>\n | ||||||
376<\/td>\n | FK-5410 Resistance to Airflow FK-5420 Test Aerosol Particle Penetration FK-5430 Resistance to Rough Handling FK-5440 Resistance to Pressure FK-5450 Resistance to Heated Air Table FK-5400-1 Test Groups and Sequence \u2014 Type 4 Axial Flow Rectangular HEPA Filters <\/td>\n<\/tr>\n | ||||||
377<\/td>\n | FK-5460 Spot Flame Resistance FK-5500 INSPECTION FK-5600 PRODUCTION TESTING FK-6100 GENERAL FK-6200 MANUFACTURE AND ASSEMBLY FK-6210 Tolerances FK-6220 Media Installation <\/td>\n<\/tr>\n | ||||||
378<\/td>\n | FK-6300 WORKMANSHIP FK-8100 RESPONSIBILITY FK-8200 CERTIFICATE OF CONFORMANCE FK-9100 FILTER MARKING FK-9200 PACKAGE MARKING <\/td>\n<\/tr>\n | ||||||
379<\/td>\n | NONMANDATORY APPENDIX FK-A DETERMINATION OF HEPA FILTER SERVICE LIFE <\/td>\n<\/tr>\n | ||||||
380<\/td>\n | NONMANDATORY APPENDIX FK-B DIVISION OF RESPONSIBILITY Table FK-B-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
381<\/td>\n | SECTION FL DEEP BED SAND FILTERS FL-1100 SCOPE FL-1200 PURPOSE FL-1300 APPLICABILITY FL-1310 Limitations FL-1320 Division of Responsibility FL-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
382<\/td>\n | FL-3100 ALLOWABLE MATERIALS FL-3110 General Requirements FL-3120 Filter Media FL-3130 DBS Filter Structure and Distribution Channels <\/td>\n<\/tr>\n | ||||||
383<\/td>\n | FL-3140 Distribution Support Structure FL-3150 Monitoring, Sampling, and Instrumentation Lines FL-3160 Gaskets FL-3200 SPECIAL LIMITATIONS OF MATERIALS FL-3300 CERTIFICATION OF MATERIALS FL-4100 GENERAL DEEP BED SAND FILTER DESIGN FL-4110 DBS Filter Design FL-4120 General Arrangement FL-4200 DESIGN CRITERIA <\/td>\n<\/tr>\n | ||||||
384<\/td>\n | FL-4210 Design Features Figure FL-4120-1 Typical DBS Filter Cross Section, DOE-HDBK-1169-2003 <\/td>\n<\/tr>\n | ||||||
385<\/td>\n | FL-4220 Monitoring Capabilities FL-4230 Particle Removal Efficiency FL-4300 STRUCTURAL REQUIREMENTS FL-4310 General FL-4320 Natural Phenomena FL-5100 ACCEPTANCE TESTS FL-5110 Filter Media Acceptance Tests <\/td>\n<\/tr>\n | ||||||
386<\/td>\n | FL-5120 Distribution Support Structure Acceptance Tests FL-5130 DBS Filter Structure Acceptance Tests FL-5200 INSPECTION PLAN FL-5210 Plan FL-5220 Minimum Filter Media Inspection Requirements FL-5230 Minimum Distribution Support Structure Inspection Requirements <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | FL-5240 Minimum Monitoring and Sampling Line Inspection Requirements FL-5250 Minimum DBS Filter Structure Inspection Requirements FL-5260 Rejection and Reinspection FL-5300 QUALIFICATION AND VERIFICATION TESTING FL-5310 Filter Media Verification Testing FL-5320 DBS Filter Performance Qualification and Verification Testing <\/td>\n<\/tr>\n | ||||||
388<\/td>\n | FL-6100 GENERAL FL-6200 FABRICATION AND ASSEMBLY FL-6210 Reinforcing Steel and Concrete FL-6220 Distribution Support Structure FL-6230 Structural Steel FL-6300 INSTALLATION FL-6310 Concrete Installation FL-6320 Distribution Support Structure Installation FL-6330 Monitoring and Sampling Line Installation FL-6340 Structural Steel Installation FL-6350 Filter Media Installation FL-6400 TOLERANCES FL-6410 Concrete Tolerances <\/td>\n<\/tr>\n | ||||||
389<\/td>\n | FL-6420 Distribution Support Structure Tolerances FL-6430 Monitoring and Sampling Line Tolerances FL-6440 Reinforcing Steel Placing Tolerances FL-6450 Filter Media Tolerances FL-7100 GENERAL REQUIREMENTS FL-7200 FILTER MEDIA FL-8100 GENERAL FL-8110 Scope and Applicability FL-8200 IDENTIFICATION AND COMPLETED MATERIAL FL-9100 DEEP BED SAND FILTER MARKINGS FL-9200 PACKAGE MARKING FL-9300 FILTER MEDIA <\/td>\n<\/tr>\n | ||||||
390<\/td>\n | MANDATORY APPENDIX FL-I AIR-AEROSOL MIXING TEST PROCEDURES FL-I-1100 SYSTEM TEST FL-I-1200 SUMMARY OF METHOD FL-I-1300 INJECTION PORT SELECTION CRITERIA FL-I-1400 DOWNSTREAM SAMPLE PORT SELECTION CRITERIA FL-I-4100 GENERAL <\/td>\n<\/tr>\n | ||||||
391<\/td>\n | FL-I-4200 DOWNSTREAM SAMPLE PORT QUALIFICATION <\/td>\n<\/tr>\n | ||||||
392<\/td>\n | MANDATORY APPENDIX FL-II DEEP BED SAND FILTER IN-PLACE LEAK TEST PROCEDURES FL-II-1100 SUMMARY OF METHOD FL-II-3100 TEST EQUIPMENT FL-II-3200 PROCEDURES <\/td>\n<\/tr>\n | ||||||
393<\/td>\n | NONMANDATORY APPENDIX FL-A DIVISION OF RESPONSIBILITY Table FL-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
394<\/td>\n | NONMANDATORY APPENDIX FL-B GUIDELINES FOR DEEP BED SAND FILTERS FL-B-1100 GENERAL FL-B-1200 FILTER MEDIA FL-B-1210 Purity FL-B-1220 Aggregate Types FL-B-1300 DBS FILTER STRUCTURE AND DISTRIBUTION CHANNELS <\/td>\n<\/tr>\n | ||||||
395<\/td>\n | FL-B-2100 GENERAL FL-B-2200 DESIGN ATTRIBUTES FL-B-2210 Provision for Inspections and Maintenance FL-B-2220 Allowance of Bypass Channel FL-B-2300 EXAMPLES OF SUPPORT STRUCTURE ARRANGEMENT FL-B-2400 END OF LIFE FL-B-3100 FILTER MEDIA ACCEPTANCE TEST PROCEDURES FL-B-3110 Water Extractable Test <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | FL-B-3120 Particle Size Distribution Test Figure FL-B-2300-1 Sand-Filter Cross Sections <\/td>\n<\/tr>\n | ||||||
397<\/td>\n | FL-B-3130 Resistance to Airflow Test FL-B-3140 Friable Material Test FL-B-3150 Corrosion-Resistance Test <\/td>\n<\/tr>\n | ||||||
398<\/td>\n | FL-B-3200 SEISMIC FL-B-3300 SMOKE LOADING FL-B-4100 GENERAL FL-B-4200 FILTER MEDIA PLACEMENT FL-B-4210 Type A Media FL-B-4220 Types B and C Media FL-B-4230 Types D, E, F, G, and H Media <\/td>\n<\/tr>\n | ||||||
399<\/td>\n | SECTION FM HIGH-STRENGTH HEPA FILTERS <\/td>\n<\/tr>\n | ||||||
400<\/td>\n | SECTION FN FILTER MEDIA: HIGH EFFICIENCY FN-1100 SCOPE FN-1110 PURPOSE FN-1120 Applicability FN-1130 Definitions and Terms <\/td>\n<\/tr>\n | ||||||
401<\/td>\n | FN-3100 ALLOWABLE MATERIALS FN-3110 Fiber FN-3120 Binder FN-3130 Water Repellent FN-3140 Additional Fibers FN-3150 Nonpermissable Materials FN-4100 GENERAL DESIGN REQUIREMENTS FN-4110 Form FN-4120 Size FN-4130 Splices FN-4200 PHYSICAL AND CHEMICAL FN-4210 Airflow Resistance FN-4220 Test Aerosol Penetration FN-4230 Tensile Strength <\/td>\n<\/tr>\n | ||||||
402<\/td>\n | FN-4240 Water Repellency FN-4250 Thickness FN-4260 Combustible Material FN-4270 Flexing Characteristics FN-4280 Mildew Resistance FN-4300 WORKMANSHIP FN-5100 QUALIFICATION TESTING FN-5110 Sample FN-5200 TEST PROCEDURES FN-5210 Airflow Resistance and Test Aerosol Penetration FN-5220 Tensile Strength <\/td>\n<\/tr>\n | ||||||
403<\/td>\n | FN-5230 Water Repellency FN-5240 Thickness FN-5250 Combustible Material FN-5260 Flexing Characteristics FN-5270 Mildew Resistance <\/td>\n<\/tr>\n | ||||||
404<\/td>\n | FN-5280 Workmanship FN-5300 PRODUCTION TESTING FN-5310 Production Lot FN-5320 Sampling FN-5330 Testing FN-6100 GENERAL REQUIREMENTS FN-6200 MANUFACTURE AND ASSEMBLY FN-6210 Tolerances FN-6300 WORKMANSHIP FN-7100 PACKAGING Table FN-5330-1 Filter Media Qualification and Production Tests <\/td>\n<\/tr>\n | ||||||
405<\/td>\n | FN-7200 SHIPPING FN-7300 STORAGE FN-8100 RESPONSIBILITY FOR INSPECTION FN-8110 Supplier\u2019s Responsibility FN-8120 Objective Evidence FN-9100 MEDIA ROLL MARKING FN-9200 PACKAGE MARKING <\/td>\n<\/tr>\n | ||||||
406<\/td>\n | NONMANDATORY APPENDIX FN-A DIVISION OF RESPONSIBILITY Table FN-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
407<\/td>\n | SECTION IA INSTRUMENTATION AND CONTROLS IA-1100 SCOPE IA-1200 PURPOSE IA-1300 APPLICABILITY IA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
408<\/td>\n | IA-3100 MATERIALS OF CONSTRUCTION IA-3200 NONPERMISSIBLE MATERIALS <\/td>\n<\/tr>\n | ||||||
409<\/td>\n | IA-3300 RESTRICTED MATERIALS IA-3400 CERTIFICATION OF MATERIAL IA-4100 GENERAL DESIGN IA-4110 Purpose IA-4120 Design Specification IA-4130 Manufacturer\u2019s Documentation Requirements Table IA-3100-1 Allowable Materials <\/td>\n<\/tr>\n | ||||||
410<\/td>\n | IA-4140 Clarification of Code Applicability IA-4200 SINGLE-FAILURE CRITERIA IA-4210 Common Cause Failure IA-4300 SEPARATION CRITERIA IA-4310 Circuits and Devices IA-4320 Instrument-Sensing Lines IA-4400 QUALIFICATION OF EQUIPMENT IA-4410 Normal Operating Conditions IA-4420 Environmental Qualification IA-4430 Seismic Qualification <\/td>\n<\/tr>\n | ||||||
411<\/td>\n | IA-4440 Qualification Documentation IA-4500 PANELS IA-4510 General IA-4520 Structures and Enclosure Materials IA-4530 Panel Wiring <\/td>\n<\/tr>\n | ||||||
412<\/td>\n | IA-4540 Power Supply and Fuses IA-4550 Panel Piping, Tubing, Valves, and Fittings IA-4560 Instrument Air-Supply Header Assembly IA-4570 Instrument Tags IA-4600 MOUNTED INSTRUMENTS AND SENSORS IA-4700 INTERCONNECTING WIRING FOR SKID-MOUNTED COMPONENTS IA-4800 INSTRUMENT-SENSING LINES AND FIELD-INSTALLED TUBING IA-4810 Pressure Boundary and Mechanical Design Requirements <\/td>\n<\/tr>\n | ||||||
413<\/td>\n | IA-4820 Tube Pitch and Condensate Trap IA-4830 Support System IA-4840 Root Valves and Isolation Valves IA-4900 INSTRUMENT SET POINTS IA-4910 IA-4920 IA-5100 GENERAL IA-5110 Procedures for Inspection and Testing IA-5120 Test Reports IA-5200 VISUAL INSPECTION IA-5220 Methods of Visual Examination IA-5230 Written Procedures IA-5300 CALIBRATION AND TESTING IA-5310 Panel-Mounted Instruments <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | IA-5320 Local Mounted Instruments IA-5330 Pressure Testing of Tubing and Sensing Lines IA-6100 GENERAL REQUIREMENTS IA-6110 Materials IA-6200 FABRICATION PROCESS IA-6300 WELDING IA-6400 BRAZING IA-6500 CLEANING AND COATING IA-6600 INSTALLATION REQUIREMENTS: HANDLING AND RIGGING IA-6700 MATERIAL IDENTIFICATION IA-7100 GENERAL REQUIREMENTS IA-7200 PACKAGING <\/td>\n<\/tr>\n | ||||||
415<\/td>\n | IA-7300 SHIPPING IA-7400 RECEIVING IA-7410 Inspection IA-7420 Disposition IA-7500 STORAGE IA-8100 GENERAL IA-8200 TEST REPORTS AND DATA IA-8210 IA-8220 IA-9100 GENERAL IA-9200 REQUIREMENTS IA-9300 NAMEPLATE SPECIFICATIONS IA-9310 Material IA-9320 Size <\/td>\n<\/tr>\n | ||||||
416<\/td>\n | IA-9330 Information <\/td>\n<\/tr>\n | ||||||
417<\/td>\n | NONMANDATORY APPENDIX IA-A DIVISION OF RESPONSIBILITY Table IA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
418<\/td>\n | NONMANDATORY APPENDIX IA-B SAMPLE CHECKLIST FOR VISUAL EXAMINATION OF CONTROL PANELS\/ENCLOSURES, INSTRUMENTS, AND CONTROL DEVICES Table IA-B-1000-1 Sample Checklist for Visual Examination of Control Panels\/Enclosures, Instruments, and Control Devices <\/td>\n<\/tr>\n | ||||||
419<\/td>\n | NONMANDATORY APPENDIX IA-C INSTRUMENTATION FOR NUCLEAR AIR AND GAS TREATMENT SYSTEMS IA-C-1100 PURPOSE IA-C-1200 FUNCTIONAL DESIGN IA-C-1210 General IA-C-1220 Recommended System Parameters Table IA-C-1220-1 Instrumentation for Nuclear Air and Gas Treatment Systems <\/td>\n<\/tr>\n | ||||||
420<\/td>\n | Division III Process Gas Treatment SECTION GA HEAT EXCHANGERS GA-1100 SCOPE GA-1200 PURPOSE GA-1300 APPLICABILITY GA-1310 Clarification of Code Applicability GA-1320 Exclusion of Components GA-1330 Interfacing Boundaries GA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
422<\/td>\n | GA-3100 GENERAL REQUIREMENTS GA-3110 Material Specifications GA-3200 MATERIALS FOR HEAT EXCHANGERS GA-3210 Materials for Pressure-Retaining Heat Exchanger Components GA-3220 Materials for Nonmetallic Heat Exchanger Components GA-3300 CERTIFICATION OF MATERIALS GA-3310 General Requirements <\/td>\n<\/tr>\n | ||||||
423<\/td>\n | GA-4100 DESIGN SPECIFICATIONS GA-4200 STRUCTURAL REQUIREMENTS FOR HEAT EXCHANGERS GA-4210 General GA-4220 Load Definition GA-4230 Structural Verification <\/td>\n<\/tr>\n | ||||||
424<\/td>\n | GA-4300 DESIGN CONDITIONS FOR SHELL-AND-TUBE HEAT EXCHANGERS GA-4310 Design Specification GA-4320 Technical Requirements Figure GA-4311-1 Typical Shell-and-Tube Heat Exchanger <\/td>\n<\/tr>\n | ||||||
426<\/td>\n | GA-4400 DESIGN CONDITIONS FOR GASKETED PLATE AND FRAME HEAT EXCHANGERS GA-4410 Design Specification GA-4420 Technical Requirements Figure GA-4411-1 Gasketed Plate and Frame Heat Exchanger <\/td>\n<\/tr>\n | ||||||
427<\/td>\n | GA-4430 Structural Requirements GA-4500 DESIGN CONDITIONS FOR BRAZED-PLATE HEAT EXCHANGERS GA-4510 Design Specification Figure GA-4510-1 Brazed-Plate Heat Exchanger <\/td>\n<\/tr>\n | ||||||
428<\/td>\n | GA-4520 Technical Requirements GA-4530 Structural Requirements GA-4600 DESIGN CONDITIONS FOR WELDED-PLATE HEAT EXCHANGERS GA-4610 Design Specification <\/td>\n<\/tr>\n | ||||||
429<\/td>\n | GA-4620 Technical Requirements Figure GA-4611-1 Typical Welded-Plate Heat Exchanger <\/td>\n<\/tr>\n | ||||||
430<\/td>\n | GA-4630 Structural Requirements GA-5100 GENERAL REQUIREMENTS GA-5200 TESTING GA-5210 Performance Verification GA-5220 Leak Testing for Heat Exchangers <\/td>\n<\/tr>\n | ||||||
431<\/td>\n | GA-5300 NONDESTRUCTIVE EXAMINATION GA-5310 Material Examination GA-5320 Visual Examination of Brazed Joints GA-6100 GENERAL REQUIREMENTS GA-6200 WELDING GA-6300 BRAZING GA-6400 MECHANICAL JOINING <\/td>\n<\/tr>\n | ||||||
432<\/td>\n | GA-6500 CLEANING, FINISHING, AND COATING GA-6510 General GA-6520 Finishing and Surface Preparation GA-6530 Coating and Application GA-6600 INSTALLATION GA-7100 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
433<\/td>\n | GA-7200 PACKAGING GA-7210 ASME BPVC, Section III Heat Exchangers GA-7220 ASME BPVC, Section VIII Heat Exchangers GA-7300 SHIPPING GA-7310 ASME BPVC, Section III Heat Exchangers GA-7320 ASME BPVC, Section VIII Heat Exchangers <\/td>\n<\/tr>\n | ||||||
434<\/td>\n | GA-7400 STORAGE GA-7410 ASME BPVC, Section III Heat Exchangers GA-7420 ASME BPVC, Section VIII Heat Exchangers GA-7500 HANDLING GA-7510 General Requirements GA-7520 ASME BPVC, Section III Heat Exchangers GA-7530 ASME BPVC, Section VIII Heat Exchangers GA-8100 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
435<\/td>\n | GA-8200 DOCUMENTATION AND RETENTION GA-9100 GENERAL REQUIREMENTS GA-9200 HEAT EXCHANGERS GA-9300 INFORMATION ON HEAT EXCHANGER NAMEPLATES GA-9400 NAMEPLATE VISIBILITY GA-9500 DATA REPORTS GA-10100 GENERAL <\/td>\n<\/tr>\n | ||||||
436<\/td>\n | NONMANDATORY APPENDIX GA-A DIVISION OF RESPONSIBILITY Table GA-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
437<\/td>\n | NONMANDATORY APPENDIX GA-B DESIGN RECOMMENDATIONS FOR GASKETED PLATE AND FRAME HEAT EXCHANGERS <\/td>\n<\/tr>\n | ||||||
438<\/td>\n | SECTION GB NOBLE GAS HOLD-UP EQUIPMENT <\/td>\n<\/tr>\n | ||||||
439<\/td>\n | SECTION GC GAS COMPRESSORS AND EXHAUSTERS GC-1100 SCOPE GC-1200 PURPOSE GC-1300 APPLICABILITY GC-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
440<\/td>\n | GC-3100 GENERAL GC-3110 Material Stress Values GC-3200 SPECIAL LIMITATIONS ON MATERIALS GC-3300 CERTIFICATION OF MATERIALS GC-3310 Centrifugal and Axial Compressors GC-3320 Rotary Screw and Reciprocating Compressors GC-3400 PURCHASED MATERIALS <\/td>\n<\/tr>\n | ||||||
441<\/td>\n | GC-3500 DRIVER MATERIALS GC-4100 DESIGN CONDITIONS GC-4110 Performance GC-4120 Environmental Conditions GC-4130 Loading and Conditions GC-4140 Leakage <\/td>\n<\/tr>\n | ||||||
442<\/td>\n | GC-4150 Equipment and Support Boundary GC-4160 Vibration GC-4200 SPECIFICATION DESIGN REQUIREMENTS GC-4210 Compressors <\/td>\n<\/tr>\n | ||||||
443<\/td>\n | GC-4220 Drivers GC-4300 CONSTRUCTION GC-4310 General GC-4320 Centrifugal and Axial Compressors GC-4330 Reciprocating Compressors GC-4340 Rotary Screw Compressors GC-4350 Drivers and Drives GC-4360 Accessories <\/td>\n<\/tr>\n | ||||||
444<\/td>\n | GC-4400 REPORTS AND CALCULATIONS GC-4410 Performance Rating GC-4420 Equipment Sound Production GC-4430 Structural Verification Considerations <\/td>\n<\/tr>\n | ||||||
445<\/td>\n | GC-5100 COMPRESSOR INSPECTION AND TESTING GC-5110 General Testing Requirements GC-5120 Performance Acceptance Tests GC-5130 Sound Tests GC-5140 Mechanical Tests <\/td>\n<\/tr>\n | ||||||
446<\/td>\n | GC-5150 Test Results and Reports GC-5200 DRIVER INSPECTION AND TESTING GC-5210 First Unit of a Design GC-5220 Succeeding Units of a Design GC-6100 GENERAL GC-6200 FABRICATION GC-6210 Selection of Materials GC-6300 INSTALLATION GC-7100 GENERAL GC-7200 PACKAGING GC-7300 SHIPPING <\/td>\n<\/tr>\n | ||||||
447<\/td>\n | GC-7400 RECEIVING GC-7500 STORAGE GC-8100 GENERAL GC-8200 REQUIRED DOCUMENTATION GC-8210 Certified Performance Curves GC-8220 Material Certification GC-8300 DRAWINGS AND DOCUMENTATION GC-9100 GENERAL GC-9200 REQUIRED NAMEPLATE DATA GC-9210 Compressor Nameplate Data GC-9220 Driver Nameplate Data GC-9300 ACCESSORIES GC-9310 Acceptable Marking Methods GC-9400 INSTALLATION, OPERATION, AND MAINTENANCE MANUALS <\/td>\n<\/tr>\n | ||||||
449<\/td>\n | MANDATORY APPENDIX GC-I SHAFT LEAKAGE Table GC-I-1000-1 Maximum Permissible Shaft Leakage Rate, scfm, at Pressure Differential Between Operating and Ambient <\/td>\n<\/tr>\n | ||||||
450<\/td>\n | MANDATORY APPENDIX GC-II SYSTEM CONSIDERATIONS GC-II-1100 SYSTEM CHARACTERISTICS GC-II-1200 SYSTEM EFFECTS ON PERFORMANCE GC-II-1300 EQUIPMENT AND SYSTEM MATCHING GC-II-1400 SYSTEM CAPACITY CONTROL GC-II-1500 MULTIPLE-UNIT SYSTEMS <\/td>\n<\/tr>\n | ||||||
451<\/td>\n | NONMANDATORY APPENDIX GC-A DIVISION OF RESPONSIBILITY <\/td>\n<\/tr>\n | ||||||
452<\/td>\n | Table GC-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
454<\/td>\n | SECTION GD \u2009 <\/td>\n<\/tr>\n | ||||||
455<\/td>\n | SECTION GE HYDROGEN RECOMBINERS AND IGNITERS GE-1100 SCOPE GE-1200 PURPOSE GE-1300 APPLICABILITY GE-1310 Limitations GE-1320 Responsibility GE-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
457<\/td>\n | GE-3100 GENERAL REQUIREMENTS GE-3110 Materials GE-3120 Welding and Brazing Material GE-3200 PAR <\/td>\n<\/tr>\n | ||||||
458<\/td>\n | GE-3300 IGNITER GE-4100 GENERAL DESIGN GE-4110 Design Specification GE-4200 PAR GE-4300 IGNITER <\/td>\n<\/tr>\n | ||||||
459<\/td>\n | GE-4400 STRUCTURAL REQUIREMENTS GE-4410 Load Criteria GE-4420 Stress Criteria GE-4430 Deflection Criteria GE-5100 GENERAL GE-5200 PERFORMANCE TESTING GE-5210 PAR Performance Testing Table GE-4410-1 Load Conditions \u2014 Housing and Support <\/td>\n<\/tr>\n | ||||||
460<\/td>\n | GE-5220 Igniter Performance Testing GE-6100 GENERAL REQUIREMENTS GE-6200 FABRICATION PROCESSES GE-6300 WELDING GE-6400 BRAZING GE-6500 CLEANING AND COATING GE-6510 General <\/td>\n<\/tr>\n | ||||||
461<\/td>\n | GE-6520 Housing Cleaning and Finishing, Coating, and Application GE-6600 INSTALLATION REQUIREMENTS GE-7100 GENERAL REQUIREMENTS GE-7200 PACKAGING GE-7300 SHIPPING GE-7400 STORAGE GE-7500 RECEIVING GE-7600 HANDLING AND RIGGING GE-7700 ASSEMBLY, ERECTION, AND START-UP GE-8100 GENERAL REQUIREMENTS GE-8200 IDENTIFICATION AND CONTROL OF ITEMS GE-8300 DOCUMENTATION <\/td>\n<\/tr>\n | ||||||
462<\/td>\n | GE-9100 GENERAL REQUIREMENTS GE-9200 INFORMATION ON NAMEPLATES GE-9300 PAR NAMEPLATE LOCATION GE-9400 DATA REPORTS GE-10100 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
463<\/td>\n | NONMANDATORY APPENDIX GE-A DIVISION OF RESPONSIBILITY Table GE-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
464<\/td>\n | NONMANDATORY APPENDIX GE-B ILLUSTRATIONS OF COMPONENTS Figure GE-B-1000-1 Typical PAR <\/td>\n<\/tr>\n | ||||||
465<\/td>\n | Figure GE-B-1000-2 Typical Igniter <\/td>\n<\/tr>\n | ||||||
466<\/td>\n | NONMANDATORY APPENDIX GE-C PERIODIC TESTING GUIDELINES GE-C-1100 IN-SERVICE TEST REQUIREMENTS GE-C-1110 PAR Testing GE-C-1120 Igniter Testing GE-C-1200 STRUCTURAL INSPECTION <\/td>\n<\/tr>\n | ||||||
467<\/td>\n | SECTION GF GAS SAMPLING <\/td>\n<\/tr>\n | ||||||
468<\/td>\n | SECTION GG SCRUBBERS <\/td>\n<\/tr>\n | ||||||
469<\/td>\n | SECTION GH CYCLONES <\/td>\n<\/tr>\n | ||||||
470<\/td>\n | SECTION GI \u2009 <\/td>\n<\/tr>\n | ||||||
471<\/td>\n | SECTION GJ FILTERS <\/td>\n<\/tr>\n | ||||||
472<\/td>\n | SECTION GK MIST ELIMINATORS <\/td>\n<\/tr>\n | ||||||
473<\/td>\n | SECTION GL \u2009 <\/td>\n<\/tr>\n | ||||||
474<\/td>\n | SECTION GM NOBLE GAS HOLD-UP MEDIA GM-1100 SCOPE GM-1200 APPLICABILITY GM-1300 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
475<\/td>\n | GM-3100 ACTIVATED CARBON GM-4100 ACTIVATED CARBON GM-5100 INTRODUCTION GM-5200 ACTIVATED CARBON FOR NOBLE GAS DELAY GM-5210 Physical Testing GM-5220 Performance Testing GM-6100 FABRICATION GUIDELINES GM-7100 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
476<\/td>\n | GM-7200 PROTECTION OF CARBON MEDIA GM-7300 PACKAGING GM-7310 General GM-7320 Polyethylene Barrier Material GM-7400 STORAGE GM-7500 HANDLING GM-7600 SHIPPING GM-7610 General GM-7620 Post-loading Inspection GM-7630 Sealed Openings GM-7640 Stacking GM-7700 MARKING <\/td>\n<\/tr>\n | ||||||
477<\/td>\n | GM-8100 GENERAL REQUIREMENTS GM-8200 DOCUMENTATION GM-9100 NAMEPLATE, CERTIFICATION, AND SHIPPING INFORMATION <\/td>\n<\/tr>\n | ||||||
478<\/td>\n | NONMANDATORY APPENDIX GM-A DIVISION OF RESPONSIBILITY Table GM-A-1000-1 Division of Responsibility <\/td>\n<\/tr>\n | ||||||
479<\/td>\n | NONMANDATORY APPENDIX GM-B DETERMINATION OF THE DYNAMIC ADSORPTION COEFFICIENT \u2014 RADIOACTIVE TRACER METHOD GM-B-1100 SCOPE GM-B-1200 APPLICABLE DOCUMENTS <\/td>\n<\/tr>\n | ||||||
480<\/td>\n | Figure GM-B-3000-1 Schematic of Noble Gas Delay Test Apparatus <\/td>\n<\/tr>\n | ||||||
481<\/td>\n | GM-B-7100 SYSTEM DEAD TIME DETERMINATION GM-B-7200 DETERMINATION OF AVERAGE DELAY TIME <\/td>\n<\/tr>\n | ||||||
483<\/td>\n | Figure GM-B-7100-1 Typical Traces for Measurement of Delay Time, Tdelay, for Dynamic K Determination <\/td>\n<\/tr>\n | ||||||
484<\/td>\n | Division IV Testing Procedures SECTION TA FIELD TESTING OF AIR TREATMENT SYSTEMS TA-1100 SCOPE TA-1200 PURPOSE TA-1300 APPLICABILITY TA-1400 DEFINITIONS AND TERMS <\/td>\n<\/tr>\n | ||||||
485<\/td>\n | TA-3100 GENERAL TA-3200 TEST INSTRUMENTS TA-3210 Range Requirements TA-3220 Instrument Fluctuation TA-3230 Evaluation Following Test Instrument Loss, Damage, or Calibration Failure <\/td>\n<\/tr>\n | ||||||
486<\/td>\n | TA-3240 Specific Instrument Accuracy Requirements TA-3300 ESTABLISHMENT OF REFERENCE VALUES TA-3400 INSPECTIONS AND TEST REQUIREMENTS Table TA-3200-1 Instrument Accuracy Requirements <\/td>\n<\/tr>\n | ||||||
487<\/td>\n | TA-3410 Inspection and Test Parameters TA-3420 System Operating Conditions TA-3430 Procedure Requirements TA-3440 Test Reports TA-3500 GENERIC TESTS TA-3510 Visual Inspections TA-3520 Pressure Boundary Tests TA-3530 Functional Tests <\/td>\n<\/tr>\n | ||||||
488<\/td>\n | TA-3600 ACCEPTANCE CRITERIA TA-3610 Visual Inspection TA-3620 Pressure Boundary Tests TA-3630 Functional Tests TA-4100 FAN ACCEPTANCE TESTS TA-4110 Acceptance Test Requirements TA-4120 Visual Inspection Table TA-4110-1 Fan Acceptance Tests <\/td>\n<\/tr>\n | ||||||
489<\/td>\n | TA-4130 Pressure Boundary Tests TA-4140 Component Functional Tests TA-4150 System Functional Tests TA-4160 Acceptance Criteria <\/td>\n<\/tr>\n | ||||||
490<\/td>\n | TA-4200 DAMPER ACCEPTANCE TESTS TA-4210 Acceptance Test Requirements TA-4220 Visual Inspection TA-4230 Pressure Boundary Tests TA-4240 Component Functional Tests Table TA-4210-1 Damper Acceptance Tests <\/td>\n<\/tr>\n | ||||||
491<\/td>\n | TA-4250 System Functional Tests TA-4300 DUCT, HOUSING, AND MOUNTING FRAME ACCEPTANCE TESTS TA-4310 Acceptance Test Requirements TA-4320 Visual Inspection TA-4330 Pressure Boundary Tests TA-4400 REFRIGERATION EQUIPMENT ACCEPTANCE TESTS TA-4410 Acceptance Test Requirements Table TA-4310-1 Duct, Housing, and Frame Acceptance Tests <\/td>\n<\/tr>\n | ||||||
492<\/td>\n | TA-4420 Visual Inspection TA-4430 Pressure Boundary Tests TA-4440 Component Functional Tests TA-4450 System Functional Tests Table TA-4410-1 Refrigeration Equipment Acceptance Tests <\/td>\n<\/tr>\n | ||||||
493<\/td>\n | TA-4500 CONDITIONING EQUIPMENT ACCEPTANCE TESTS TA-4510 Acceptance Test Requirements TA-4520 Visual Inspection TA-4530 Hydrostatic Test for Hydronic Piping and Coils TA-4540 Component Functional Tests Table TA-4510-1 Conditioning Equipment Acceptance Tests <\/td>\n<\/tr>\n | ||||||
494<\/td>\n | TA-4550 System Functional Tests TA-4560 Hydronic System Heating and Cooling Performance Test TA-4570 Acceptance Criteria TA-4600 MOISTURE SEPARATOR, PREFILTER, AND HEPA FILTER BANK ACCEPTANCE TESTS TA-4610 Acceptance Test Requirements Table TA-4610-1 Moisture Separator, Prefilter, and HEPA Filter Acceptance Tests <\/td>\n<\/tr>\n | ||||||
495<\/td>\n | TA-4620 Visual Inspection TA-4630 System Functional Tests TA-4640 Acceptance Criteria TA-4700 TYPES II, III, AND IV ADSORBER BANK ACCEPTANCE TESTS TA-4710 Acceptance Test Requirements TA-4720 Visual Inspection TA-4730 Component Functional Tests TA-4740 System Functional Tests Table TA-4710-1 Types II, III, and IV Adsorber Bank Acceptance Tests <\/td>\n<\/tr>\n | ||||||
496<\/td>\n | TA-4750 Acceptance Criteria TA-4800 ADSORBENT ACCEPTANCE TESTS TA-4810 Acceptance Test Requirements TA-4820 Laboratory Analysis of Adsorbent TA-4900 INTEGRATED SYSTEM TESTS <\/td>\n<\/tr>\n | ||||||
497<\/td>\n | TA-4910 Fan-Integrated System Test Requirements TA-4920 Damper-Integrated System Test Requirements TA-4930 Refrigeration and Conditioning Integrated System Test Requirements TA-4940 HEPA and Adsorber Bank Integrated System Test Requirements TA-4950 Integrated System Habitability Envelope Test Requirements TA-6100 GENERAL TA-6200 PERSONNEL TA-6300 DOCUMENTATION TA-6310 Procedures <\/td>\n<\/tr>\n | ||||||
498<\/td>\n | TA-6320 Reports <\/td>\n<\/tr>\n | ||||||
499<\/td>\n | MANDATORY APPENDIX TA-I VISUAL INSPECTION CHECKLIST TA-I-1100 FAN INSPECTION ITEMS TA-I-1200 DAMPER INSPECTION ITEMS TA-I-1300 DUCT, HOUSING, AND MOUNTING FRAME INSPECTION ITEMS TA-I-1400 REFRIGERATION EQUIPMENT INSPECTION ITEMS <\/td>\n<\/tr>\n | ||||||
500<\/td>\n | TA-I-1500 CONDITIONING EQUIPMENT INSPECTION ITEMS TA-I-1600 MOISTURE SEPARATOR BANK, PREFILTER BANK, AND HEPA FILTER BANK INSPECTION ITEMS TA-I-1700 TYPES II, III, AND IV ADSORBER BANK INSPECTION ITEMS <\/td>\n<\/tr>\n | ||||||
501<\/td>\n | MANDATORY APPENDIX TA-II STRUCTURAL CAPABILITY TEST PROCEDURES TA-II-1100 SUMMARY OF METHOD <\/td>\n<\/tr>\n | ||||||
502<\/td>\n | MANDATORY APPENDIX TA-III DUCT AND HOUSING LEAK TEST PROCEDURES TA-III-1100 SUMMARY OF METHOD TA-III-4100 CONSTANT PRESSURE TEST <\/td>\n<\/tr>\n | ||||||
503<\/td>\n | TA-III-4200 PRESSURE DECAY TEST TA-III-4300 ACCEPTANCE CRITERIA TA-III-4400 BUBBLE LEAK LOCATION METHOD TA-III-4500 AUDIBLE LEAK LOCATION METHOD <\/td>\n<\/tr>\n | ||||||
504<\/td>\n | MANDATORY APPENDIX TA-IV AIRFLOW DISTRIBUTION TEST PROCEDURES TA-IV-1100 SUMMARY OF METHOD <\/td>\n<\/tr>\n | ||||||
505<\/td>\n | MANDATORY APPENDIX TA-V AIR-AEROSOL MIXING TEST PROCEDURES TA-V-1100 SYSTEM TEST TA-V-1200 SUMMARY OF METHOD TA-V-1300 INJECTION PORT SELECTION CRITERIA TA-V-1400 DOWNSTREAM SAMPLE PORT SELECTION CRITERIA TA-V-4100 GENERAL <\/td>\n<\/tr>\n | ||||||
506<\/td>\n | TA-V-4200 DOWNSTREAM SAMPLE PORT QUALIFICATION <\/td>\n<\/tr>\n | ||||||
507<\/td>\n | MANDATORY APPENDIX TA-VI HEPA FILTER BANK IN-PLACE LEAK TEST PROCEDURES TA-VI-1100 SUMMARY OF METHOD <\/td>\n<\/tr>\n | ||||||
508<\/td>\n | MANDATORY APPENDIX TA-VII ADSORBER BANK IN-PLACE LEAK TEST PROCEDURES TA-VII-1100 SUMMARY OF METHOD <\/td>\n<\/tr>\n | ||||||
509<\/td>\n | MANDATORY APPENDIX TA-VIII REFRIGERANT PIPING AND COIL SYSTEM LEAK TEST PROCEDURES TA-VIII-1100 SUMMARY OF METHOD TA-VIII-4100 LEAK TEST PROCEDURES TA-VIII-4200 EVACUATION AND DEHYDRATION PROCEDURE <\/td>\n<\/tr>\n | ||||||
511<\/td>\n | NONMANDATORY APPENDIX TA-A MOUNTING FRAME PRESSURE LEAK TEST PROCEDURES TA-A-1100 SUMMARY OF METHOD <\/td>\n<\/tr>\n | ||||||
512<\/td>\n | NONMANDATORY APPENDIX TA-B CORRECTIVE ACTION GUIDANCE <\/td>\n<\/tr>\n | ||||||
513<\/td>\n | NONMANDATORY APPENDIX TA-C CHALLENGE GAS AND AEROSOL SUBSTITUTE SELECTION CRITERIA TA-C-1100 ALTERNATIVE CHALLENGE GASES TA-C-1200 ALTERNATIVE CHALLENGE AEROSOLS <\/td>\n<\/tr>\n | ||||||
514<\/td>\n | SECTION TB FIELD TESTING OF GAS-PROCESSING SYSTEMS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME AG-1-2019 Code on Nuclear Air and Gas Treatment<\/b><\/p>\n |