FGI SoundVibration 2010
$46.80
Sound & Vibration: Design Guidelines for Health Care Facilities
Published By | Publication Date | Number of Pages |
FGI | 2010 | 81 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | Note to Readers |
7 | Table of Contents |
10 | Introduction |
13 | Process Overview & Acknowledgements |
15 | Development Timeline |
19 | 1 Site Exterior Noise |
20 | 1.1 General |
21 | 1.2 Applicable Federal, State, and Local Codes and Regulations |
22 | 1.3 Classification of non-facility produced exterior noise exposure 1.3.1 Exterior noise classifications |
25 | A1.3 Procedure for determining composite sound transmission class rating (STCc |
28 | 1.4 Classification of facility produced exterior noise exposure |
29 | 1.4.1 Heliports |
30 | 1.4.2 Emergency power generators |
31 | 1.4.3 Outdoor mechanical equipment 1.4.4 Building services |
32 | 2 Acoustical Finishes and Details |
33 | 2.1 General |
35 | 2.2 Applicable Federal, State and Local Codes and Regulations |
36 | 2.3 Design Criteria for Acoustical Finishes |
37 | A2.3 Determination of Design Room Average Sound Absorption Coefficient ( design) and Room Sound Absorption Factors (AR, sf |
39 | 2.4 Considerations for NICUs (from Standard 21: Ceiling Finishes |
40 | A2.4.2 Interpretation |
41 | 3 Room Noise Levels |
42 | 3.1 General 3.2 Federal, State and Local Codes, Regulations, and Guidelines |
43 | 3.3 Design Criteria for Room Noise Levels |
45 | 3.4 Conformance measurements of room sound level A3.4.1 Determination of Room Noise Level A3.4.2 Effect of Background Noise on Clinical Hearing Ability A3.4.3 Discussion of Background Noise Rating Criteria |
48 | 3.5 Considerations for NICUs (from Standard 23: Acoustic Environment A3.5.1 Interpretation A3.5.2 Interpretation |
50 | 4 Sound Isolation Performance of Constructions |
51 | 4.1 General 4.2 Applicable Federal, State and Local Codes and Regulation 4.3 Design guidelines for sound isolation between enclosed rooms |
53 | A4.3.1 Typical partitions A4.3.2 Extraordinary partitions |
55 | A4.3.3 Composite Sound Transmission Class (STCc |
56 | 4.4 Design guidelines for speech privacy between enclosed rooms |
57 | A4.4 Enclosed Room Speech Privacy Design Guidance 4.5 Design guidelines for speech privacy in open-plan spaces 4.6 Open Plan Speech Privacy Design Guidance |
58 | 4.6.1 Considerations for NICUs (from Standard 23: Acoustic Environment 4.6.2 Considerations for NICUs (from Standard 23: Acoustic Environment |
59 | Speech Privacy References A4.6 Interpretation |
61 | 5 Paging & Call Systems, Clinical Alarms, Masking Systems & Sound Reinforcement |
62 | 5.1 General 5.2 Applicable Federal, State and Local Codes and Regulation 5.3 Paging and Call Systems |
63 | 5.4 Clinical alarms |
64 | A5.4 Audibility of tonal alarms 5.5 Masking Systems 5.6 Sound Reinforcement |
65 | 5.7 Considerations for NICUs (from Standard 23: Acoustic Environment A5.7 Interpretation References |
66 | 6 Building Vibration |
67 | 6.1 General |
68 | 6.2 Applicable Federal, State and Local Codes and Design Guides 6.3 Vibration Control and Isolation 6.3.1 Mechanical, Electrical and Plumbing Equipment (MEP 6.3.2 Structural |
69 | 6.3.3 Structureborne sound 6.3.4 Medical and laboratory instrumentation |
70 | Glossary |
79 | Partial List of Abbreviations |
81 | References New references |