BSI 15/30321124 DC:2015 Edition
$13.70
BS EN 60364-4-41 AMD1. Low voltage electrical installation. Part 4-41. Protection for safety. Protection against electric shock
Published By | Publication Date | Number of Pages |
BSI | 2015 | 35 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
8 | 410 Introduction |
9 | 410.1 Scope 410.2 Normative references |
10 | 410.3 General requirements |
11 | 411 Protective measure: automatic disconnection of supply 411.1 General |
12 | 411.2 Requirements for basic protection 411.3 Requirements for fault protection 411.3.1 Protective earthing and protective equipotential bonding 411.3.1.1 Protective earthing 411.3.1.2 Protective equipotential bonding 411.3.2 Automatic disconnection in case of a fault |
13 | 411.3.3 Additional requirements for socket-outlets and for the supply of mobile equipment for use outdoors |
14 | 411.4 TN system |
15 | 411.5 TT system |
16 | 411.6 IT system |
18 | 411.7 Functional extra-low voltage (FELV) 411.7.1 General |
19 | 411.7.2 Requirements for basic protection 411.7.3 Requirements for fault protection 411.7.4 Sources 411.7.5 Plugs and socket-outlets 412 Protective measure: double or reinforced insulation 412.1 General |
20 | 412.2 Requirements for basic protection and fault protection 412.2.1 Electrical equipment 412.2.2 Enclosures |
21 | 412.2.3 Installation 412.2.4 Wiring systems |
22 | 413 Protective measure: electrical separation 413.1 General 413.2 Requirements for basic protection 413.3 Requirements for fault protection |
23 | 414 Protective measure: extra-low-voltage provided by SELV and PELV 414.1 General 414.2 Requirements for basic protection and fault protection |
24 | 414.3 Sources for SELV and PELV 414.4 Requirements for SELV and PELV circuits |
25 | 415 Additional protection 415.1 Additional protection: residual current protective devices (RCDs) 415.2 Additional protection: supplementary protective equipotential bonding |
27 | Annex A (normative) Provisions for basic protection A.1 Basic insulation of live parts A.2 Barriers or enclosures |
29 | Annex B (normative) Obstacles and placing out of reach B.1 Application B.2 Obstacles B.3 Placing out of reach |
31 | Annex C (normative) Protective measures for application only when the installation is controlled or under the supervision of skilled or instructed persons C.1 Non-conducting location |
32 | C.2 Protection by earth-free local equipotential bonding C.3 Electrical separation for the supply of more than one item of current-using equipment |
34 | Annex D (informative) Provisions where automatic disconnection according to 411.3.2 is not feasible |